- 27 -
Recognition
) if a tamper or wire fault occurs on a
bypassed zone.
8.4 K
EYPAD
P
ANIC
O
PTIONS
Sections [506], [510], [514], [518] - Options [1] to [6]
As the control panel can enable Keypad Panic
Options for each individual partition, select the
section that corresponds to the desired partition and
set options [1] through [6] on/off to obtain the desired
options as described below.
Option [1]
ON
–
P
ANIC
1
Pressing the [1] & [3] keys simultaneously on the
keypad for 2 seconds will generate a silent or audible
alarm as defined by option [4].
Option [2]
ON
–
P
ANIC
2
Pressing the [4] & [6] keys simultaneously on the
keypad for 2 seconds will generate a silent or audible
alarm as defined by option [5].
Option [3]
ON
–
P
ANIC
3
Pressing the [7] & [9] keys simultaneously on the
keypad for 2 seconds will generate a silent or audible
alarm as defined by option [6].
Option [4]
ON
=
Panic 1
– Silent
OFF
=
Panic 1
– Audible
Option [5]
ON
=
Panic 2
– Silent
OFF
=
Panic 2
– Audible
Option [6]
ON
=
Panic 3
– Silent
OFF
=
Panic 3
– Pulsed (Fire)
Silent operation:
The control panel emits a single confirmation beep
and transmits the appropriate report code (see
section 9.2.5) to the central station.
Audible operation:
The alarm output (bell/siren) activates until a user
cancels the alarm with a valid User Access Code or
when the
Bell Cut-Off Timer
elapses (see section 8.2).
Fire operation:
Same as audible operation, except that the
bell/siren output will be pulsed as shown in figure
5.3 on page 17.