background image

NVX80 V1.07 Installation Quick Start

Important

: Keep a 20 mm/0.80 in 

clearance from the top of the unit’s 
plastic casing to the ceiling or 
object placed above the unit. 

Legend

L – Level

W1 – Wall installation

W2 – Wall Tamper Installation

C1 – Corner-Mount Installation

C2 – Corner-Mount Tamper Installation 

Installation Steps

1.   Loosen the tamper screw found at the 

bottom of the unit.

2.   Separate the back cover from the unit.

3.   Drill or punch out the appropriate knock-out holes 

for either a wall or corner installation, refer to the 

installation legend above.

4.   Make sure to allow for 20 mm/0.80 in of space 

between the top of the unit and a ceiling or 

object found above it.

5.   Mark your selected location using the back cover 

of the unit as a template.

6.   Drill holes into the wall surface.

7.   Thread the wires through the wire entry hole.

8.   Secure the back cover of the unit to the wall 

surface using mounting screws appropriate for 

the specific installation.

9.   Slide the front section of the unit into place 

on the back cover of the unit. If the wires are 

connected to electricity, then the power up 

sequence will automatically start.

10.   Ensure that the outer rim of the unit is tightly 

joined, so that waterproof casing is not 

compromised.

11.   While the tamper screw at the bottom of the unit is 

open, begin the power up process and access the 

menus to change any sensitivity or other settings, 

then press OK to save the altered settings.

12.   Tightly close the tamper screw found at the 

bottom of unit and put the detector into 

operation mode.

For the complete manual visit www.paradox.com.

L

C1

C1

C1

W1

W1

W1

W2

C2

Wiring

Entry

Hole

C1

W2

C2

R+

B-

GRN YEL TMP NC1

C1

NO1 NC2 COM NC3

1

NVX80-EQ02

06/2013