Esprit 728 Ultra & 738 Ultra
5
2.8
Keypad Zone Connections
Each keypad comes with one input terminal which allows you to connect one detector or door contact directly to the keypad.
Example: A door contact located at the entry point of an establishment can be wired directly to the input terminal of the entry point
keypad instead of wiring the door contact all the way to the control panel.
Figure 8: Connecting One Keypad Zone
Regardless of the number of keypads in the system, the control panel supports a maximum of two keypad zones. The control
panel will recognize these added zones as shown in Table 2 on page 6.
If using two keypad zones, one keypad must be defined as keypad zone 1 while the other must be defined as keypad
zone 2 (see Figure 9 on page 5).
Example: A security installation is composed of five keypads. Of these five keypads only two can have their zone input terminals
enabled (see Figure 9 on page 5). The other three keypads must have their zone input terminals disabled as described in
Disabling 636 and 646* Keypad Zones
on page 5 and Disabling 642* Keypad Zones on page 5.
Figure 9: Connecting Two Keypad Zones Using Two Keypads
Disabling 636 and 646* Keypad Zones
If the keypad zone input terminal is not being used, disable it by shorting the blue zone wire with the black
COM
wire of the keypad.
Disabling 642* Keypad Zones
If the keypad zone input terminal is not being used, disable it by setting option
[2]
(Keypad Options) key
[1]
to OFF.
* Do not use the 646 LED and 642 LCD keypads for UL installations. Both the 646 LED keypad and the 642 LCD keypad
are not UL listed.
LED KEYPADS:
(J1) Zone select jumper OFF
(J2) EOL select jumper ON
642 LCD KEYPADS:
Keypad Programming Mode
Option
[2]
(Keypad Options); Key
[1]
ON
Option
[2]
(Keypad Options); Key
[2]
ON
Option
[2]
(Keypad Options); Key
[3]
OFF
Option
[2]
(Keypad Options); Key
[4]
ON
In the control panel, enable
Keypad
Supervision
at address
090
.
Key
[
STAY
]
ON = Keypad Zone 1
Door Contact
Keypad zone 1
KEYPAD ZONE 1:
LED Keypad:
(J1) Zone select jumper OFF
(J2) EOL select jumper ON
642 LCD Keypads: Keypad programming mode
Option
[2]
(Keypad Options)
key
[1]
ON
Option
[2]
(Keypad Options)
key
[2]
ON
Option
[2]
(Keypad Options)
key
[3]
OFF
Option
[2]
(Keypad Options)
key
[4]
ON
KEYPAD ZONE 2:
LED Keypad:
(J1) Zone select jumper ON
(J2) EOL select jumper ON
642 LCD Keypads: Keypad programming mode
Option
[2]
(Keypad Options)
key
[1]
ON
Option
[2]
(Keypad Options)
key
[2]
ON
Option
[2]
(Keypad Options)
key
[3]
ON
Option
[2]
(Keypad Options)
key
[4]
ON
In the control panel, enable keypad
supervision at address
090
: keys
[
STAY
]
and
[
AWAY
]/[
FORCE
]
ON
Door Contact
Keypad zone 1
Door Contact
Keypad zone 2
Summary of Contents for ESPRIT 728 ULT
Page 1: ...Versions 4 4 728ULT 4 1 738ULT Reference Installation Manual 728ULT 738ULT ...
Page 2: ......
Page 54: ...Notes ...
Page 55: ......