20
EVOHD User Manual
7.6 User Options
Options [1] and [2]
: Master Feature
When option
[1]
is
OFF
, the User cannot program other users into the system.
When option
[1]
is
ON
and option
[2]
is
OFF
, the user can program and modify user access codes (P.I.N. only) and
User Labels.
When both options
[1]
and
[2]
are
ON
, the user has Full Master rights. The user can create or modify user access
codes, User Options, User Access Control Options, Access Card Numbers, User Labels and Area Assignments
according to their own programming. For example, if the Full Master User has access to area #1 and option
[4]
(Bypass) only, the Full Master user can only assign area #1 and option
[4]
to other users in the system.
Option [3]
: Duress
When option
[3]
is
ON
, the Duress feature is enabled. This feature is used when someone forces a user to arm or
disarm an area(s). By entering a user access code (P.I.N.) reserved for the Duress feature, the system will arm or
disarm the area(s), and then send a silent alarm to the monitoring station.
Option [4]
: Bypass
When option
[4]
is
ON
, the Bypass feature is enabled. This feature allows the user to deactivate zones when
arming the area(s).
Option [5]
: Arm Only
When option
[5]
is
ON
, the Arm Only feature is enabled. The user can arm assigned areas with either a card or
code, but cannot disarm. When the option is
OFF
, the user can either arm or disarm assigned areas.
Option [6]
: Stay & Instant Arm
When option
[6]
is
ON
, the Stay and Instant arm features are enabled. The user can now Stay or Instant arm their
assigned areas.
Option [7]
: Force Arm
When option
[7]
is
ON
, the Force arm feature is enabled. The user can now Force arm their assigned areas.
Option [8]
: Area Access
When option
[8]
is
ON
, the keypad will permit access to all the areas assigned to the user access code. When
option
[8]
is
OFF
, the keypad will only permit access to the areas it controls. For example, the keypad is assigned
area 1 only, and your user access code is assigned areas 1 to 8. If the option is ON, you can access all eight areas
from the keypad. If the option is
OFF
, you can only access area 1.
N
OTE
:
By default all users can Regular arm the system.
7.7 Access Control User Options
Option [1]
: Access Control
When option
[1]
is
ON
, the user can gain access to an access control door when Access Control is enabled in the
system. A user that is not assigned to any partition, but has the Access Control option (Option [1]) enabled, can
now gain access to an access control door by entering a code # (P.I.N.) and then pressing the
[
ACC
]
keypad key.
When the option is
OFF
, the user cannot access an Access Control door.
Option [2]
: Can Disarm with Access Card
When option
[2]
is
ON
, a User’s Access Control card can unlock and disarm an armed Access Control door. When
option
[2]
is
OFF
, follow the settings in option
[8]
on page 20.