ACM24D - page 2
Wiring
Related Topics
Specifications
Installation / Wiring
(see Imperial System Guide)
•
DIN Rail Enclosure
•
System Diagrams and Wiring Tips
•
Wire Gauge Selection
Features
•
Assigning a Reader to a Door (see page 3)
•
Bi-directional Locate Feature (see page 4)
•
Remote Firmware Upgrade (see page 4)
Applications
•
Access Control
BabyWare
(see Imperial System Guide)
•
BabyWare
Power
Input Voltage
16-24Vac (50 or 60Hz), or 16-36Vdc
20VA, 40VA or 75VA (see table in wiring diagram
below)
Aux. Readers:
12Vdc, 500mA max.
Aux. Locks:
6-12Vdc, 1.3A (see table in wiring diagram
below)
Battery
12Vdc, 4Ah or 7Ah gel cell (see table in wiring
diagram below)
RS485 Bus
900m (3,000ft) requires external 12Vdc power
No. of outputs
2 form C relays rated at 3.5A / 28Vdc (NO / NC)
No. of inputs
6 (1 door contact, 1 REX, and 1 trigger per door)
Dimensions
DIN9: 16cm X 10cm X 6cm (6.3” X 4” X 2.5”)
Operating
Temperature
-10ºC to 50ºC
14ºF to 122ºF
1
Reader Bus (500mA)
Connect up to 4 readers (2 per door).
Supports R910 (V2.0 or higher), and
R915 (any version).
See "Assigning a
Reader to a Door” on page 3.
2
Door Power Selection Jumper
J2 ON
= Internal power (12Vdc) with
Energy Saving feature
J2 OFF
= External Power
See "Door Output Power Selection
Jumper” on page 4 for more
information.
3
AC/DC Input with Transformer
Sharing
Modules with this feature can share a
central transformer (16-24Vac, or 16-
36Vdc) throughout the system. Ensure
that the total power output of the
transformer is respected. There is no
specific polarity.
4
RS485 Access Bus
Connect to V32 RS485 Access bus.
Ensure that it is powered by an
external power supply (PS27D). This
will not be necessary with an
upcoming V32 hardware version,
which will supply the power (see
www.paradox.com for availability).
5
Battery Input
Connect a 12Vdc (4Ah or 7Ah)
rechargeable gel cell battery. Apply
AC power before connecting the
battery. If battery wires are extended,
use an external fuse to protect against
a short.
REX Device
Contact
1 kΩ**
Optional external trigger
to unlock door
Fail secure
latch (N.O.)
12Vdc
*
Reader
In 1
Reader
Out 3
Reader
In 2
Reader
Out 4
Door 1
Door 2
J2 ON
~ ~
16-24Vac, or
16-36Vdc
Transformer
16 / 24 Vac
Transformer sharing
compatible modules
12Vdc
Battery
+
-
PS27D Power supply
V32
A+B-
ETHERNET
10/100 Mbps
RS485 ACCESS
1
22
3
4
5
Transformer requirements table
Power
Rating
Max. Lock
Output
Max. Battery
Charging
Reader
Bus
75VA
1.3A
500mA
500mA
40VA
1.3A
350mA
500mA
800mA
500mA
500mA
20VA
External
power (J2 off)
350mA
500mA
Time to fully charge battery
Battery
Type
Batt Charge
350mA
Batt Charge
500mA
4Ah
11.5 hours
8 hours
7Ah
20 hours
14 hours