26
HD77 Installation Guide
PIR Programming Through the K641+ keypad
Only PIR parameters for the HD77 can be configured through the touchpad.
1. Press and hold the [
0
] key. The installer will be asked to input his installer code.
2. Enter your [
Installer Code
]. The default installer code is 000000.
3. Key in Section [
4003
].
4. Enter the module’s [
Serial Number
].
5. Enter Section [
001
].
6. Option 1 is for PIR LED On/Off; On – LED#3 is Red when PIR motion is detected. Off – LED#3 stays off when
the PIR motion is detected.
Default is On
Options 2 through 8 are not relevant for the HD77.
7. Enter Section [
002
].
8. Select PIR sensitivity level, level 1 to level 5. Default is level 3.
9. Enter Section [
003
].
10. Select PIR security level, level 1 to level 3. Default is level 1.
PIR Settings
Table 3: PIR Configuration Settings
Description
Section
Setting
Setting Details
Example
1. PIR LED display
[001]
[1] Off
[1] On
PIR LED Off
PIR LED On
(1*******)
2. PIR Sensitivity
[002]
[1]
Low (Sensitivity level)
(001) 000-005
[2]
[3]
Default
[4]
[5] High
(Sensitivity
level)
3 Security Level
[003]
[1]
Normal
(Mild environment)
(001) 000-003
[2]
Medium
[3]
High (Harsh
environment)