background image

Programmable output

Not only does your Esprit control panel provide top
security, it also offers you total convenience. Your
installer can program the panel to reset smoke
detectors & Glasstreks, to activate strobe lights, to
activate light switches in your home or office, to
reduce or increase building temperature, turn on/off
air conditioning, open/close automatic garage
doors, and more. Talk to your installer about this
helpful feature!

Keypad night illumination
Pressing on the [

MEM

key for 2 seconds changes it to

the keypad illumination key. Pressing this key will
then alter the illumination level from low, medium, to
high, and then “off ”. Keep pressing the [

MEM

key until

you reach the level you require, then press [

ENTER

or

[

CLEAR

to save the setting in system memory.

Chime zones
Zones 1 to 6, as well as the local keypad zones, can
be programmed as 

chime

zones. A chime zone

"advises" you when it is opened by creating a rapid
intermittent beep tone. To turn on the "chime zone"
feature, press on the selected zone key for three sec-
onds until the intermittent chime beep is heard. This
means that the chime feature has been activated. If
a continuous beep is heard, this means that the
chime is "off". (The keypad zone chime is enabled by
pressing key [8].)

If you have more than one keypad in your system,
please "chime" program each keypad separately.
Keypad chimes must be reprogrammed if the panel
suffers total power loss. 

CHIME KEYS

:

Key [1]-[6] Turns chime "

ON

" or "

OFF

" in zones num-

bered 1-6.

Key [8]

Turns the chime "

ON

" and "

OFF

" for the

zone connected to this keypad.

Each keypad must be programmed inde-

pendently.

PANEL BUZZER MUTE

:

Key [9]

Turns keypad sounder "

ON

" and "

OFF

"

(intermittent beep means 

MUTE

is activat-

ed, and keypad sounder is "

OFF

".

Depress for 2 seconds to disable.)

TROUBLE DISPLAY and TROUBLE MEMORY
10 different trouble conditions can be displayed on your
keypad. When a trouble condition occurs, the [

TRBL

]

key on your keypad illuminates and if programmed by
your installer, the keypad sounder will beep. (When
“power supply failure” trouble occurs, the [

TRBL

key

flashes rapidly.

À

À

) Press on this key and it flashes, indi-

cating that your panel is in "trouble display" mode.

Control panel software versions prior to 2.00:
Keys that illuminate in "trouble display" mode tell you 
which trouble conditions are taking place and/or are 

À

À

Control panel software versions 2.00 and beyond.

18

19

UM616-626

UM616-626

Summary of Contents for Paradox Esprit 616LED

Page 1: ...READY ESPRIT 616 Model 626 Model 10 AWAY 6 12 9 3 0 4 7 1 11 5 8 2 BYP CLEAR ENTER STAY TRBL 2ND MEM READY ARMED P R D O X S E C U R I T Y S Y S T E M S PRINTED IN CANADA P R D O X S E C U R I T Y S Y...

Page 2: ...ope that you ve already been impressed by its compact design and attractively styled keypads with their adjustable illu mination levels The dwelling or building that you want to secure can be divided...

Page 3: ...rt of the last 256 events This reduces time and expense devoted to security supervision and can be performed in minutes Look Everything you need to know about your security system is clearly and simpl...

Page 4: ...can activate User Codes 01 16 or 01 48 on control panels soft ware version 3 00 and beyond can be programmed by your installer to arm disarm the system activate STAY or AWAY arming and zone bypassing...

Page 5: ...and the ENTER key will stay on 3 Key in 4 or 6 digits of the user code number and press ENTER The CONFIRMATION beep will be heard again The ENTER key will flash A four or six digit user code has been...

Page 6: ...move around your home or commercial building while certain designated zones are armed You might choose to have entry exit points like doors or win dows protected or the basement or perhaps all the zon...

Page 7: ...panel models 728 728 EXPRESS and 738 EXPRESS using software version 2 1X keys indicated will not flash but will be constantly illuminated Software versions 2 2X onward keys indicated do not illuminate...

Page 8: ...pass information every time you arm Control panel software versions prior to 2 00 5 AUTO BYPASS Away arming AWAY CODE Control panel software versions prior to 2 00 If you want to arm the system withou...

Page 9: ...2 sec will generate a panic 3 or if pro grammed a fire alarm Based on your needs your installer can program these panic zones to generate audible alarms sirens or bells or silent alarms both of which...

Page 10: ...d 738 EXPRESS using software versions 2 1X onward keys indicated will not flash but will be con stantly illuminated Note System A codes can stop sirens coming from System B zones and vice versa but wi...

Page 11: ...t the chime feature has been activated If a continuous beep is heard this means that the chime is off The keypad zone chime is enabled by pressing key 8 If you have more than one keypad in your system...

Page 12: ...ower failure can be excluded from key TRBL display by your installer When a power supply failure trouble occurs TRBL key flashes rapidly Key 3 AC power failure Control panel software versions prior to...

Page 13: ...oss of the telephone line Key 11 Fire trouble If the fire zone is cut the fire zone key and trouble key 11 will illuminate Most of these trouble conditions will be programmed by your installer to be r...

Page 14: ...or the Disabled For special circumstances where life safety of some occupant s depends upon prompt rescue by others the fire warning system includes a means of prompt automatic notification to those w...

Page 15: ...tes Press ENTER MEM Panel time Key MEM flashes Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes Press ENTER BYP Test report If programmed by your installer this sends a test report co...

Page 16: ...l l l l l l l Zone 9 l l l l l l l l Zone 10 l l l l l l l l Zone 11 l l l l l l l l Zone 12 l l l l l l l l ZONE DESCRIPTION PARTITIONING l l Yes l l No SYSTEM 24 Bypass ACTIVATED A B Hr Enabled Zone...

Page 17: ...l l l l l User 22 l l l l l l l l User 23 l l l l l l l l Name Code Arming Priority Reg Stay Away Byp A B User 24 l l l l l l l l User 25 l l l l l l l l User 26 l l l l l l l l User 27 l l l l l l l...

Page 18: ...ed You have one exit time and up to two individual entry times i e Zone 1 Front door delay 1 30 sec Zone 7 Garage door delay 2 90 sec You have seconds to EXIT your premises Your Entry delay 1 is secon...

Page 19: ...o code required Enabled by installer FAST STAY ARM key Press for 2 sec and system stay arms automatically No code required Enabled by installer Activates STAY arming To stay on the premises but still...

Page 20: ...r complete warranty information In all cases the warranty does not cover malfunctions arising from installer error or failure to follow installation operation instructions nor does it apply to damages...

Reviews: