22 Reference & Installation Manual
Section [25]
4.5 P
ANIC
L
OCKOUT
T
IMER
Section [26]
[26]
[26]
[26] - decimal select: [0]
[0]
[0]
[0] to [4]
[4]
[4]
[4]
When a remote control-activated panic alarm is
generated (see section 4.3.3 on page 20), the
Parakey can ignore any incoming RF signals for a
specified period. This prevents an aggressor from
disarming the system in case of a panic situation.
In section [26], select only one:
Section [26]
Key [0] ON
= No output on panic alarm
Key [1] ON
= Toggle output 1 on panic alarm
Key [2] ON
= Toggle output 2 on panic alarm
Key [3] ON
= Toggle output 3 on panic alarm
(default)
Key [4] ON
= Toggle output 4 on panic alarm
Key [0] ON = No signal lock-out on panic alarm
(default)
Key [1] ON = 30-second signal lockout on
panic alarm
Key [2] ON = 60-second signal lockout on
panic alarm
Key [3] ON = 90-second signal lockout on
panic alarm