background image

Programming

When connected to a SP Series or E55 system, the RX1 settings are 
programmed in the control panel. Refer to the panel’s 

Programming Guide.

The 

following control panel programming sections apply to program wireless devices 
(

bold

 = default):

NOTE:

 Record the serial number of wireless modules to be used with the RX1.

Onboard PGMs

The RX1 includes two on-board PGMs which follow buttons 1 and 2 on REM1/
RAC1 remote controls. PGMs are also programmable and appear as PGMs 13 
and 14 in the SP Series or E55 panel (V5.0 and higher). Refer to the panel’s 

Programming Guide

 for instructions on PGM programming.

Section

Description

[061] - [092] Wireless serial numbers
[101] - [132] Wireless transmitter signal strength
[610] - [642] Remote control button assignment
[651] - [682] Remote control user assignment

[705]

Supervision Options

[6]

[7]

RF Zone 
Supervision Options

Keypad / Bus Module 
Supervision Options

Off

Off

Disabled Disabled 

Off

On

Trouble only

Trouble only

On

Off

Disarmed: trouble only
Armed: follow zone’s alarm type

Trouble only

On

On

Disarmed: audible alarm
Armed: follow zone’s alarm type

Audible alarm

[706]

General Zone Options 

Option

OFF

ON

[1]

Check-in supervision time

N

24 hours

N

80 minutes

Warranty

For complete warranty information, please visit www.paradox.com/terms. Your use of the Paradox 
product signifies your acceptance of all warranty terms and conditions. Esprit E55 and SP Series 
are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in 
Canada, the United States and/or other countries. For the latest product approvals, such as UL and 
CE, please visit www.paradox.com. © 2009 Paradox Security Systems Ltd. All rights reserved. 
Specifications may change without prior notice.

Patents

One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 
5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending 