3
Things You Need to Know
About this Programming Guide
Use this programming guide to record programmed settings for your Magellan or Spectra SP control panel. This guide should be
used along with the Magellan and Spectra SP Reference & Installation Manual (available online), whenever installing or
programming your Magellan or Spectra SP system.
Conventions
The following typographical conventions are used throughout this guide:
Installer Code
The default installer code is
0000
or
000000
.
This code allows you to enter programming mode, where you can program all
features, options, and commands of the control panel, except for user codes. To change this code, see
Maintenance Code
Similar to the installer code, the maintenance code allows you to enter programming mode and program all sections, except for
user codes and communication settings (sections
[395]
,
[397]
,
[398]
,
[815]
,
[816]
,
[817]
,
[910]
,
[911]
,
[970]
,
[918]
,
[919]
,
[920]
to
[927]
,
[929]
to
[935]
,
[936]
to
[942]
,
[943]
to
[949]
, and
[975]
) – these sections can only be accessed using the installer code. Since
there is no default code, see
on page 30 to set a default.
System Master Code
The default system master code is
1234
or
123456
. The system master code allows you to utilize any arming method, as well as
program user codes. To change the default code, see
Panel Reset
Performing a panel reset will reset all panel settings to their preset, default values.
SP4000 / SP65 panels
To perform a panel reset for a SP4000 or SP65 control panel, proceed as follows:
1.
Verify that the installer lock is disabled.
2.
Remove the battery and AC power from the control panel.
3.
Remove all connected wires and devices from the PG1 and zone 1 terminals.
4.
Using a wire, short the PG1 and zone 1 terminals.
5.
Reconnect the AC and battery power to the panel. Once connected, the following will occur: 1)
STATUS
LED flashes; 2)
STATUS
LED remains illuminated, indicating a reset is in progress; 3)
STATUS
LED flashes, indicating the reset is complete.
6.
Remove the jumper wire.
All other MG/SP panels
To perform a panel reset for all other MG/SP panels:
1.
Press and hold the panel’s
RESET
button until the
STATUS
LED flashes (5 seconds).
2.
Release the
RESET
button, and then push it once more, within two seconds.
To reset the panel to its default settings using section programming, see section
[950]
in
Entering Programming Mode
To enter programming mode, proceed as follows:
1.
Press
ENTER
.
2.
Enter your installer or maintenance code. Upon entering your code, the
ARM
and
STAY
LEDs will flash. To modify codes, see
3.
Enter the three-digit section you wish to program. The
ARM
and
STAY
LEDs remain illuminated.
4.
Enter required data.
WARNING: To enter programming mode, all zones must be disarmed and StayD mode deactivated. To deactivate StayD,
press
OFF
, enter your master or user code, and then press
OFF
.
Default Settings: Values which appear in bold typeface signify the default value: e.g.,
Access code length:
6 digits
4 digits
(
4 digits
is the default value)
: Installer Quick Menu (indicates that information on the topic can
also be found in the Installer Quick Menu on page 7)
Section numbers and keypad keys also appear in bold typeface, enclosed by
brackets: e.g.,
Section
[706]
must be enabled...
WARNING: Important information
Throughout this guide, Magellan (MG) and Spectra (SP) will be referred to as MG/SP
NOTE:
Suggestion or reminder