Magellan & Spectra SP • Programming Guide
49
Automatic Report Codes
Table 45: List of automatic report codes
System Event Default Contact ID Report Code
Default SIA Report Code
Arming with user code (##)
3 4A1
Close by user
CL
Closing report
Auto arming
3 4A3
Automatic close
CA
Automatic closing
Late to close
3 452
Late to close
OT
Late to close
No movement
3 452
Late to close
NA
No activity
Partial arming
1 456
Group bypass
CG
Close area
Quick arming
3 4A8
Quick arm
CL
Closing report
Arm with PC software
3 4A7
Remote arm/disarm
CQ
Remote arming
Keyswitch arming
3 4A9
Keyswitch arming
CS
Keyswitch arming
Disarm with user code (##)
1 4A1
Open by user
OP
Opening report
Disarm after alarm with user code (##)
1 4A1
Open by user
OP
Opening report
Cancel alarm with user code (##)
1 4A6
Cancel by user
OR
Disarm from alarm
Auto arming cancellation
1 464
Deferred open/close
CE
Closing extend
Disarm with PC software
1 4A7
Remote arm/disarm
OQ
Remote disarming
Disarm after an alarm with PC software
1 4A7
Remote arm/disarm
OR
Disarm from alarm
Cancel alarm with PC software
1 4A6
Cancel by user
OR
Disarm from alarm
Cancel paramedic alarm
1 4A6
Cancel by user
MH
Medical alarm restore
Keyswitch disarm
1 4A9
Keyswitch disarm
OS
Keyswitch disarm
Keyswitch disarm after alarm
1 4A1
Keyswitch disarm after alarm
OS
Keyswitch disarm after alarm
Keyswitch cancel alarm
1 4A6
Keyswitch cancel alarm
OS
Keyswitch cancel alarm
Zone bypassed (##)
1 57A
Zone bypass
UB
Untyped zone bypass
Zone alarm (##)
1 13A
Burglary alarm
BA
Burglary alarm
Fire alarm (##)
1 11A
Fire alarm
FA
Fire alarm
Zone alarm restore (##)
3 13A
Burglary alarm restore
BH
Burglary alarm restore
Fire alarm restore (##)
3 11A
Fire alarm restore
FH
Fire alarm restore
24-hr gas alarm (##)
1 151
Gas detected
GA
Gas alarm
24-hr heat alarm (##)
1 153
Loss of heat
KA
Heat alarm
24-hr water alarm (##)
1 154
Water leakage
WA
Water alarm
24-hr freeze alarm (##)
1 152
Refrigeration
ZA
Freeze alarm
24-hr gas alarm restore (##)
3 151
Gas restore
GR
Gas alarm restore
24-hr heat alarm restore (##)
3 153
Heat restore
KR
Heat alarm restore
24-hr water alarm restore (##)
3 154
Water restore
WR
Water alarm restore
24-hr freeze alarm restore (##)
3 152
Freeze restore
ZR
Freeze alarm restore
24-hr hold-up alarm
1 12A
Panic alarm
PA
Panic alarm
24-hr hold-up alarm restore
3 12A
Panic alarm restore
PR
Panic restore
Panic 1: emergency
1 12A
Panic alarm
PA
Panic alarm
Panic 2: medical
1 1AA
Medical alarm
MA
Medical alarm
Panic 3: fire
1 115
Pull station
FA
Fire alarm
Recent closing
3 459
Open/close
CR
Recent closing
Global zone shutdown
1 575
Group bypass
CG
Close area
Duress alarm
1 121
Duress
HA
Hold-up alarm
Keypad lockout
1 421
Access denied
JA
User code tamper
Zone shutdown (##)
1 57A
Zone bypass
UB
Untyped zone bypass
Zone tampered (##)
1 144
Sensor tamper
TA
Tamper alarm
Zone tamper restore (##)
3 144
Sensor tamper restore
TR
Tamper restoral
TLM Trouble
1 351
Telco 1 fault
LT
Phone line trouble
AC failure
1 3A1
AC loss
AT
AC trouble
Battery failure
1 3A9
Battery test failure
YT System
battery
trouble
Auxiliary supply trouble
1 3AA
System trouble
YP
Power supply trouble
Bell output current limit
1 321
Bell 1
YA
Bell fault
Summary of Contents for SP6000