Configuration Options
C-24
3166-A2-GB20-20
March 1999
Table C-7.
Management Trap Configuration Options (2 of 2)
Entp Trap: Enab
Next Enab Disab Prev
Enterprise Specific Traps. Specifies whether enterpriseSpecific traps are enabled.
Enab – Sends trap messages for enterpriseSpecific events to the currently configured
trap manager(s).
Disab – Disables the sending of trap messages for enterpriseSpecific events.
NOTE:
This configuration option is not available if the
SNMP Trap
configuration
option (in the
Alarm Configuration Options
section on page C-16) is
disabled.
Link Trap: Both
Next Disab Up Down Both Prev
Link Trap Type. Specifies the link trap type to enable. Interfaces monitored for linkUp
and linkDown traps are specified with the Trap I/F configuration option.
Disab – Disables the sending of trap messages for linkDown or linkUp events.
Up – Sends trap messages for linkUp events to the currently configured trap
manager(s).
Down – Sends trap messages for linkDown events to the currently configured trap
manager(s).
Both – Sends trap messages for linkUp and linkDown events to the currently configured
trap manager(s).
NOTE:
This configuration option is not available if the
SNMP Trap
configuration
option (in the
Alarm Configuration Options
section on page C-16) is
disabled.
Trap I/F: Both
Next NET Prt1 Both Prev
Link Trap Interfaces. Specifies which interfaces generate linkUp and linkDown trap
messages.
NET – Sends trap messages for linkUp and linkDown events occurring on the network
interface.
Prt1 – Sends trap messages for linkUp and linkDown events occurring on the
synchronous data port.
Both – Sends trap messages for linkUp and linkDown events occurring on the network
interface or the synchronous data port.
NOTE:
This configuration option is not available if the Link Trap configuration option
is not configured to generate trap messages for linkUp or linkDown events.
Summary of Contents for 3166 DSU
Page 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...
Page 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...