SDCP Operation
3-31
3166-A2-GB20-20
March 1999
Procedure
To select the data port:
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied into the Edit area by using the
appropriate Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. Select Chan.
F1
Edit:DTE
NET
Chan
Gen
F2
F3
5. From the Channel Config screen, press the
key to scroll the ports onto
the screen.
6. Select Prt1.
F1
Channel Config:
Dsply
Clear
Prt1
F2
F3
7. Press F1 (Next) to display the appropriate configuration options on the
screen. Use one of the following examples, depending on whether you are
assigning by block, ACAMI, or individual channel.