background image

 2

3000-A2-GZ41-50

July 1999

Installing the Rear Connector Plate

Prior to installation, check the rear connector plate and V.35 adapter for damage.
If either is damaged, report this immediately to your shipper and your service
representative.

!

HANDLING PRECAUTIONS FOR
STATIC-SENSITIVE DEVICES

This product is designed to protect sensitive components from
damage due to electrostatic discharge (ESD) during normal operation.
When performing installation procedures, however, take proper static
control precautions to prevent damage to equipment. If you are not
sure of the proper static control precautions, contact your nearest
sales or service representative.

To install a DSU and its rear connector plate for the first time:

Procedure

1. At the rear of the carrier, set the tab on the rear connector plate into one of

the slots on the carrier’s backplane (Figure 2). Make sure the rear connector
plate uses the same slot position intended for the DSU.

2. Loosely fasten the screw attached to the rear connector plate, allowing for

slight adjustment that may be needed when installing the DSU.

3. At the front of the carrier, hold the DSU vertically with the latch on its

faceplate in the open position. Then, insert the circuit card into the top and
bottom circuit card guides for the slot that contains the rear connector plate.

Slot

25-Pin V.35
Connectors

25-Pin
EIA-232-D
Connectors

Screw

Non-Modular Devices

Model 3511 DSU Rear Connector Plates

Figure 2

.

Rear View of the COMSPHERE 3000 Series Carrier

496-15104

Summary of Contents for 3511 DSU

Page 1: ... rear edge of its circuit card Figure 1 When the rear connector plate is installed in a COMSPHERE 3000 Series Carrier you can remove the modular DSU or 3800 Series modem without disturbing the DTE cables attached to the rear connector plate at the back of the carrier The rear connector plate has two 25 pin DTE connectors One is a an EIA 232 D V 24 connector and the other is an ITU T V 35 connector...

Page 2: ...tive To install a DSU and its rear connector plate for the first time Procedure 1 At the rear of the carrier set the tab on the rear connector plate into one of the slots on the carrier s backplane Figure 2 Make sure the rear connector plate uses the same slot position intended for the DSU 2 Loosely fasten the screw attached to the rear connector plate allowing for slight adjustment that may be ne...

Page 3: ...onnector plate If you are using a V 35 cable with a 34 pin connector use the V 35 adapter as described in the next procedure Connecting to a 34 Pin V 35 Interface To connect the V 35 adapter Procedure 1 Connect the 25 pin end of the V 35 adapter to the bottom DTE connector on the rear connector plate Tighten the screws on both sides of the adapter 2 Connect the DTE s V 35 cable to the V 35 adapter...

Page 4: ...ervice representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods H Internet Visit the Paradyne World Wide Web site at www paradyne com Be sure to register your warranty there Select Technical Support W...

Reviews: