HotWire 5030 POTS Splitter Customer Premises
Installation Instructions

Document Number 5030-A2-GN10-10

October 1997

Before You Begin

Verify that:

The local loop POTS service is connected to the POTS/DSL network at the
punchdown block or network interface device (NID).

New or existing unshielded twisted-pair wiring (CAT3 or better) is used with 
this product. The CAT3 wiring must meet EIA/TIA-568 specifications with 
24 AWG (.5 mm) or 26 AWG (.4 mm).

For RADSL (Rate Adaptive Digital Subscriber Line) RTU installation information, refer to
the appropriate RTU document:

Document Number

Document Title

5216-A2-GN10

HotWire 5216 Remote Termination Unit (RTU) 
Customer Premises Installation Instructions

5246-A2-GN10

HotWire 5246 Remote Termination Unit (RTU) 
Customer Premises Installation Instructions

5446-A2-GN10

HotWire 5446 Remote Termination Unit (RTU) 
Customer Premises Installation Instructions

Package Checklist

Verify that your package contains the following:

POTS splitter and housing with closure screw

Small plastic bag with two 8–15 x 1

 Type A combination Phillips/slotted-head

screws and two 1

 plastic anchors

Warranty card

Tools Required

Flat-blade screwdriver to tighten terminal screws

3/8

 nut driver to close housing securely

Phillips-head or combination Phillips/slotted-head screwdriver to mount the housing

Drill and 3/16

drill bit to mount the housing in cement or cinder block

Summary of Contents for 5030

Page 1: ...5216 A2 GN10 HotWire 5216 Remote Termination Unit RTU Customer Premises Installation Instructions 5246 A2 GN10 HotWire 5246 Remote Termination Unit RTU Customer Premises Installation Instructions 5446 A2 GN10 HotWire 5446 Remote Termination Unit RTU Customer Premises Installation Instructions Package Checklist Verify that your package contains the following POTS splitter and housing with closure s...

Page 2: ...he central office to the customer premises to create the local loop The local loop terminates on the customer premises at the demarcation point in a punchdown block or NID Wiring is connected from the demarcation point to the POTS splitter and to the DSL jack Wiring also connects the demarcation point to an RJ11 wall jack for DSL access by the RTU 97 15346 01 Punchdown Block or NID DSL Jack RTU Ne...

Page 3: ... ground At the front of the housing align the housing to open from the right with the rubber grommet for cable access facing downward Place the housing upright as shown Use a Phillips head or combination Phillips slotted head screwdriver and the screws included in the package If mounting to H Cement or cinder block use a drill and and 3 16 masonry drill bit to install the two plastic anchors first...

Page 4: ...g by pressing on the lever on the right above the closure screw 2 Remove the rubber grommet at the base of the POTS splitter 3 Make a small diagonal cut in the rubber grommet to feed the wiring through 4 Replace the rubber grommet at the base of the POTS splitter P1 P2 P3 P4 97 15256 Rubber Grommet Base of POTS Splitter ...

Page 5: ...DSL POTS From Local Loop Wiring to DSL Jack Bridge Clip Punchdown Block 97 15349 Jumper Wiring to POTS Splitter for POTS Demarcation Point Customer Premises Procedure 1 Access the punchdown block or NID 2 Disconnect the POTS access wiring from the local loop WARNING Do not continue unless the DSL access line from the local loop has been disconnected at the NID or punchdown block Refer to Important...

Page 6: ...e telephone from the T1 R1 connectors on the customer premises side 4 Feed the disconnected POTS wiring through the POTS splitter rubber grommet access opening created at the base of the POTS splitter Connect the wiring to the right side labeled PHONE Attach green to P3 and red to P4 Tighten both terminal screws with a flat blade screwdriver 97 15257a P1 P2 P3 P4 LINE PHONE Red Green To Telephone ...

Page 7: ...e the insulation at the end of the wiring 2 On the left side labeled LINE attach red to terminal screw P1 and green to terminal screw P2 Tighten both terminal screws with a flat blade screwdriver 97 15257 01 P1 P2 P3 P4 LINE PHONE Red Red Green Green New Wiring from Punchdown Block or NID To Telephone POTS Splitter ...

Page 8: ...er pair from P1 P2 labeled LINE in the POTS splitter to the T1 R1 connectors DSL POTS From Local Loop Wiring to DSL Jack Telephone Network Interface Device NID Ground Tip T1 Green 97 15341 Jumper Wiring to POTS Splitter for POTS Demarcation Point Customer Premises Ring R1 Red 4 Snap the lever shut to close the POTS splitter 5 Use the 3 8 nut driver on the closure screw to securely close the housin...

Page 9: ...Office Punchdown Block or NID Customer Premises POTS DSL Local Loop Demarcation Point Twisted Pair Wiring POTS Splitter You are now ready to run the specified wiring to the RTU location and install a DSL wall jack To install an RTU refer to the HotWire 5446 Remote Termination Unit RTU Customer Premises Installation Instructions If the RTU is not being installed at this time reconnect the local loo...

Page 10: ...the equipment s label for Registration Number Refer to the equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 40 F to 140 F 40 C to 60 C 40 F to 158 F 40 C to 70 C 5 to 95 noncondensing Withstands normal shipping and handling Interface Connectors Four terminal screws Technical Specifications subject to cha...

Page 11: ...at the network interface Use caution when installing or modifying telephone lines Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning Do not use the telephone to report a gas leak in the vicinity of the leak Notice to Users of the Telephone Network This equipment complies with Part 68 of the FCC rules On the insi...

Page 12: ...r repair or warranty information please refer to Warranty Sales and Service Information No repairs may be performed by the end user The equipment can not be used on public coin phone service provided by the telephone company Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information Wa...

Reviews: