background image

 10

7510-A2-GN10-30

January 1999

Warranty, Sales, and Service Information

Contact your local sales representative, service representative, or distributor
directly for any help needed. For additional information concerning warranty,
sales, service, repair, installation, documentation, training, distributor locations, or
Paradyne worldwide office locations, use one of the following methods:

H

Via the Internet:

  Visit the Paradyne World Wide Web site at

http://www.paradyne.com

H

Via Telephone:

  Call our automated call system to receive current

information via fax or to speak with a company representative.

— Within the U.S.A., call 1-800-870-2221

— Outside the U.S.A., call 1-727-530-2340

 

*7510–A2–GN10–30*

Copyright 

E

 1999 Paradyne Corporation

 

Summary of Contents for 7510 DSU

Page 1: ...0 727 2396 Outside the U S A call 1 727 530 8623 Cables You May Need to Order The following table describes typical equipment Identify the connectors required for your equipment before you contact your sales or service representative to order cables For cable details refer to Appendix C Cables and Pin Assignments in the User s Guide If connecting Order a A VT100 compatible terminal to the Terminal...

Page 2: ...ing terminal emulation software Before installing your DSU read the Important Safety Instructions on page 7 Installing the DSU Procedure To install the DSU 1 Plug the end of the power cord into the POWER jack on the DSU Plug the power transformer into an ac outlet CAUTION Use no power supply except the one provided with the DSU Using the wrong power supply can destroy the DSU 2 Plug the 8 pin conn...

Page 3: ...unicate at a rate of 9 6 kbps using characters of 8 bits one stop bit and no parity If you connect an external modem instead of an asynchronous terminal or PC Use an EIA 232 crossover cable as described in Appendix C Cables and Pin Assignments in the User s Guide If possible configure your modem to use standard RS232 detection and control for CTS DSR DTR LSD and RTS If possible disable AT commands...

Page 4: ... T R 1 0 8 System Network Port 497 15245 7510 DSU 56 64K Verify that the User Interface Idle screen is displayed on the terminal or PC Press the Enter key Verify that the Main Menu appears main Device Name Model 7510 MAIN MENU Status Test Configuration Control Ctrl a to access these functions Exit Î ÎÎ If the DSU fails to respond as described refer to Chapter 6 Messages and Troubleshooting in the ...

Page 5: ...erfaces Configuration Display and edit the configuration options Control Establish identification for the DSU and system or to initiate a power up reset of the DSU Configuration Edit Display System Network Data Port Terminal Port Status System and Test Status Network Interface Status Network Performance Statistics Display LEDs Identity Test Network Tests Data Port Tests Lamp Test Abort All Tests C...

Page 6: ...ack 64K CC Enable Disable Data Scrambling 64K CC Enable Disable V 54 Initiated DSU Loopback Enable Disable Data Port Configuration Option Settings Default in Bold Invert Transmit Clock Enable Disable Port DTE Initiated Loopbacks Disable Local Remote Both Bilateral Loopback Enable Disable Carrier Control by RTS Constant Switched CTS Control Standard Follow RTS Forced On Circuit Assurance RLSD Contr...

Page 7: ... 7 Input power to this product must be provided by one of the following 1 a UL Listed CSA certified power source with a Class 2 or Limited Power Source LPS output for use in North America or 2 a certified power source with a Safety Extra Low Voltage SELV output for use in the country of installation 8 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildin...

Page 8: ...e toutes les exigences du règlement sur le matérial brouilleur du Canada Government Requirements Certain governments require that instructions pertaining to connection to the telephone network be included in the installation and operation manual Specific instructions are listed in the following sections Notice to Users of the United States Telephone Network This equipment complies with Part 68 of ...

Page 9: ...be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterat...

Page 10: ...n documentation training distributor locations or Paradyne worldwide office locations use one of the following methods H Via the Internet Visit the Paradyne World Wide Web site at http www paradyne com H Via Telephone Call our automated call system to receive current information via fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 ...

Reviews: