background image

 12

7610-A2-GN10-20

November 1997

Notices

!

WARNING:

This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.

The authority to operate this equipment is conditioned by the
requirements that no modifications will be made to the equipment
unless the changes or modifications are expressly approved by
Paradyne Corporation.

!

WARNING:

To Users of Digital Apparatus in Canada:

This Class A digital apparatus meets all requirements of the Canadian
interference-causing equipment regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du
règlement sur le matérial brouilleur du Canada.

Government Requirements

Certain governments require that instructions pertaining to connection to the
telephone network be included in the installation and operation manual. Specific
instructions are listed in the following sections.

Notice to Users of the Telephone Network in the United States

This equipment complies with Part 68 of the FCC rules. On the bottom of the
equipment is a label that contains, among other information, the FCC registration
number for this equipment. If requested, please provide this information to your
telephone company.

If your DSU causes harm to the telephone network, the telephone company may
discontinue your service temporarily. If possible, they will notify you in advance.
But if advance notice is not practical, you will be notified as soon as possible. You
will be advised of your right to file a complaint with the FCC.

Your telephone company may make changes in facilities, equipment, operations,
or procedures that could affect the proper operation of your equipment. If so, you
will be given advance notice so as to give you an opportunity to maintain
uninterrupted service.

Summary of Contents for 7610 SNMP DSU

Page 1: ...CHANGE Please note that the area code for Paradyne Corporation in Largo Florida has changed from 813 to 727 For any Paradyne telephone number that appears in this manual with an 813 area code dial 72...

Page 2: ...ng the Adobe Acrobat Reader The User s Guide is provided on diskette in Portable Document Format PDF It can be browsed or printed using the Adobe Acrobat Reader The Reader is available at no charge at...

Page 3: ...m to either the H Management port H Terminal port Standard crossover EIA 232 cable with DB25 plug connectors on both ends A Router s AUX port to the Management port Standard straight through EIA 232 c...

Page 4: ...and ventilated site that is free from environmental extremes One to two feet of clearance for cable connections An operable network connection An asynchronous terminal or PC with terminal emulation so...

Page 5: ...ansformer into an ac outlet D T E TERMINAL MANAGEMENT NETWORK POWER 496 15107 Power Jack Connecting the Terminal Port to an Async Terminal Procedure 1 Insert the 25 pin end of the EIA 232 cable into t...

Page 6: ...he other end of the cable into the management interface connector This may be on A LAN adapter A UNIX workstation An external modem A router or server D T E TERMINAL MANAGEMENT NETWORK POWER 496 15108...

Page 7: ...35 cable into the DTE connector D T E TERMINAL MANAGEMENT NETWORK POWER 496 15111 DTE DTE Port Connecting to the Network Procedure 1 Insert the 8 pin connector on the RJ48S network cable into the NET...

Page 8: ...work is connected refer to Troubleshooting in Chapter 8 in the User s Guide 496 15073 Network System Port 56 64K C T S 1 0 6 O K A L A R M T E S T D M O O S O O F N S T X D 1 0 3 R X D 1 0 4 R T S 1 0...

Page 9: ...r approvals on product Refer to the equipment s label for Certification Number Interface and Connectors 25 pin D subminiature connector 34 pin MS34 connector EIA 232 ITU V 24 ISO 2110 for Terminal and...

Page 10: ...faces group DDS network DTE Data port Terminal port Management port H IP group H SNMP group H System group H TCP group H Transmission group DDS network DDS Enterprise MIB DTE Data port RS 232 Like MIB...

Page 11: ...interfaces Locally through the Terminal port or by NMS connection through the Management port Remotely via Telnet session through the Management port or the In Band Management Channel IMC Out of band...

Page 12: ...e 7 Input power to this product must be provided by one of the following 1 a UL Listed CSA certified power source with a Class 2 or Limited Power Source LPS output for use in North America or 2 a cert...

Page 13: ...sing equipment regulations Cet appareil num rique de la classe A respecte toutes les exigences du r glement sur le mat rial brouilleur du Canada Government Requirements Certain governments require tha...

Page 14: ...ational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the equipment will operate to the user s satisfa...

Page 15: ...s in need of repair refer to the procedures described in the next section Warranty Sales and Service Information Contact your sales or service representative directly for any help needed For additiona...