18
7986-A2-GZ40-00
March 1999
Switchpack Definitions
Manually change configuration options by moving Switchpack S1 DIP switches
on the card. Table 10 lists Switchpack S1 definitions.
Table 10.
Switchpack S1 Definitions
Switch # . . .
Allows you to . . .
Default in Bold
1
Enable or disable Switchpacks S1 and S2.
OFF = Switchpacks Disabled
ON = Switchpacks Enabled
2
Control line termination.
OFF = 120 Ohm
ON = 75 Ohm
3
Select the unit’s primary timing source. Only valid for units configured
as LTU.
OFF = Internal Clock
ON = External Clock
4
Control the unit’s E1 line coding.
OFF = HDB3
ON = AMI
5
Not used
6
Enable CRC-4 monitoring.
OFF = Enable CRC-4
ON = Disable CRC-4 monitoring
7
Control whether Channel 16 contains signaling information or data.
OFF = Channel 16 is used for signaling
ON = Channel 16 is used for data
8
Not used