3. Configuration Using the Web Interface
3-2
August 2005
8900-A2-GB20-50
Configuring ReachDSL Ports (8955 and 8975)
Use the Configuration - DSL Port screen to set parameters for a DSL port on the
Model 8955 ReachDSL or Model 8975 R line card.
Procedure
To configure a ReachDSL port:
1. Select a Port from the drop-down list and click on Select. Current values for
the port are displayed.
2. Enter or select the following fields:
Field
Description
Line Circuit Name
Enter a name from 1 to 255 characters long to indicate to
whom the port is assigned. The following values are
reserved and cannot be used: AVAILABLE (port is not
assigned), and FAULTY (port is faulty and can not be
assigned).
Line Type
For the Model 8975 R card, specify the line
type:
ADSL – The port supports only ADSL
ReachDSL – The port supports only ReachDSL
Dual Mode – The port supports both ADSL and
ReachDSL
This option does not appear for the Model 8955 line card.
Line Code
For the Model 8975 R card, select the ADSL
type supported:
MultiMode - The port uses the line code of its partner
modem
ANSI T1.413 - The port uses DMT modulation
ITU G.dmt Annex A - The port uses G.992.1 Annex A
modulation
ITU G.dmt Annex B - The port uses G.992.1 Annex B
modulation
ITU G.lite - The port uses G.992.2 modulation
The Line Code parameter has no effect on a Model 8955
ReachDSL card.
DSL Line Profile Name
Enter the name of a DSL line profile to set rates for the
port.
DSL Alarm Profile Name
Enter the name of a DSL alarm profile to set alarm
thresholds for the port.