3. Configuration Using the Web Interface
8900-A2-GB20-50
August 2005
3-5
3. Click on Apply.
Configuring SHDSL Ports (8985)
Use the Configuration - SHDSL Port screen to set parameters for a DSL port on
the 8985 line card.
Procedure
To configure a DSL port:
1. Select a Port from the drop-down list and click on Select. Current values for
the port are displayed.
2. Enter or select the following fields:
3. Click on Apply.
L2 Time
Specify the minimum number of seconds allowed between:
An entry into the low power (L2) state and the first
power trim in the low power state
Two consecutive power trims in the low power state
Port Status
Select Enabled, Disabled, or Reset from the drop-down list
to determine the status of the port.
Field
Description
Field
Description
Line Circuit Name
Enter a name from 1 to 255 characters long to indicate to
whom the port is assigned. The following values are
reserved and cannot be used: AVAILABLE (port is not
assigned), and FAULTY (port is faulty and can not be
assigned).
SHDSL Line Profile Name
Enter the name of a DSL line profile to set rates for the
port.
SHDSL Alarm Profile Name
Enter the name of a DSL alarm profile to set alarm
thresholds for the port.
Equivalent Working Length
Specify the estimated length of the line. The length is
used to limit transmit rates according to local spectrum
management guidelines.
Port Status
Select Enabled, Disabled, or Reset from the drop-down
list to determine the status of the port.