4. Configuration Options
9128-A2-GB20-80
September 2002
4-61
Configuring Frame Relay for an Interface
Select Frame Relay from the interface’s menu to display or change the Frame
Relay options for an individual interface (see
Table 4-13, Interface Frame Relay
Options
).
Main Menu
→
Configuration
→
[Network/Data Ports]
→
Frame Relay
See
Configuring Frame Relay for an Interface
on page 4-61
,
for additional
information.
Table 4-13. Interface Frame Relay Options (1 of 3)
LMI Protocol
Possible Settings: Initialize_From_Net1FR1,
Initialize_From_Interface,
Auto_On_LMI_Fail,
Standard,
Annex-A,
Annex-D
Default Setting:
For a user data port link: Initialize_From_Interface
For a network link: Auto_On_LMI_Fail
Specifies either the LMI protocol supported on the frame relay interface or the discovery
source for the LMI protocol.
Initialize_From_Net1FR1 – The LMI type supported on this frame relay link will be
configured to match the LMI protocol initially discovered on the primary Network frame
relay link (Net1FR1). LMI Protocol is set to None internally, but once a protocol has
become active or is set on the primary Network link, the protocol will be set to the same
value on this link (Standard, Annex-A or Annex-D). The protocol will
not be updated based
on changes to Net1FR1 after being set initially.
Display Conditions – This option value only appears for a user data port.
Initialize_From_Interface – The LMI type supported on this frame relay link will be
configured to match the LMI protocol discovered from the attached Network line or DTE
device. Once a protocol has become active, the protocol will be set to the protocol
discovered (Standard, Annex-A or Annex-D) on the frame relay link. The protocol will
not
be updated after being initially discovered. Frame relay links on user data ports discover
the LMI protocol from an attached device via LMI status polls. Frame relay links on the
network interface discover LMI protocol by sending polls to an attached Network line and
“listening” for correct poll response messages.
Auto_On_LMI_Fail – The LMI type supported on this frame relay link will be configured to
match the LMI protocol discovered from the attached Network line or the DTE device
whenever an LMI Link Down failure occurs. This option is available for frame relay links on
the Port and network interfaces. Frame relay links on user data ports discover the LMI
protocol from LMI status polls by attached DTE devices. Frame relay links on the network
interface discover LMI protocol by sending polls to an attached Network line and
“listening” for correct poll response messages.
Standard – Supports Standard LMI and the Stratacom enhancements to the Standard
LMI.
Annex-A – Supports LMI as specified by Q.933, Annex A.
Annex-D – Supports LMI as specified by ANSI T1.617, Annex D
.
Summary of Contents for 9126
Page 150: ...4 Configuration Options 4 106 September 2002 9128 A2 GB20 80 ...
Page 182: ...6 Security and Logins 6 16 September 2002 9128 A2 GB20 80 ...
Page 264: ...7 Operation and Maintenance 7 82 September 2002 9128 A2 GB20 80 ...
Page 348: ...A Menu Hierarchy A 4 September 2002 9128 A2 GB20 80 ...
Page 440: ...E Connectors Cables and Pin Assignments E 18 September 2002 9128 A2 GB20 80 ...