7. Operation and Maintenance
7-12
September
2002
9128-A2-GB20-80
Device Messages
These messages appear in the messages area at the bottom of the screens. All
device messages are listed in alphabetical order.
Table 7-6.
Device Messages (1 of 6)
Message
What It Indicates
What To Do
Access level is
n,
Read-only.
User’s access level is 2 or
3; user is not authorized to
change configurations.
No action needed.
Already Active
Test selected is already
running.
Allow test to continue.
Select another test.
Stop the test.
Blank Entries
Removed
New had been selected
from the Administer Logins
screen, no entry was made,
then Save was selected.
No action needed.
Reenter the Login ID,
Password, and Access Level.
Cannot Delete Trap
Manager
Del ete was selected from
the Management PVCs
Options screen, but the
PVC had been defined as a
trap destination.
No action needed, or configure
another path for traps and try
again.
Cannot Save – no
Level 1 Login IDs
Security was being set up,
but all the logins were
assigned either Level-2 or
Level-3 access.
Set up at least one login with
Access Level-1 so the unit can be
configured.
Command Complete
Configuration has been
saved or all tests have been
aborted.
No action needed.
Connection Refused
(Seen at an FTP
terminal.)
Two menu-driven user
interface sessions are
already in use when a
Telnet session was
attempted.
Wait and try again.
Destination Not
Unique
Destination entered is
already being used.
Enter another destination
indicator.
DLCI in connection.
Delete connection first
User tried to delete a DLCI
that was part of a
connection.
No action needed, or
Delete the connection, then
delete the DLCI.
DLCI Number Already
Exists
The DLCI number entered
on the DLCI Record Entry
screen has already been
created so is not unique.
Enter another DLCI number.
DLCI Number
Reserved
User tried to designate a
special troubleshooting
DLCI.
No action is needed.
Summary of Contents for 9126
Page 150: ...4 Configuration Options 4 106 September 2002 9128 A2 GB20 80 ...
Page 182: ...6 Security and Logins 6 16 September 2002 9128 A2 GB20 80 ...
Page 264: ...7 Operation and Maintenance 7 82 September 2002 9128 A2 GB20 80 ...
Page 348: ...A Menu Hierarchy A 4 September 2002 9128 A2 GB20 80 ...
Page 440: ...E Connectors Cables and Pin Assignments E 18 September 2002 9128 A2 GB20 80 ...