B. SNMP MIBs and Traps, and RMON Alarm Defaults
9128-A2-GB20-80
September 2002
B-15
enterpriseSecondary-
ClockFail(4)
devLastTrapString
(devHealthAndStatus.-
mib)
Operating software has detected
that the secondary clock source
has failed.
String:
‘Secondary clock failed.’
enterpriseSecondary-
ClockFailClear(104)
Operating software has detected
that the secondary clock source is
operational again.
String:
‘Secondary clock restored.’
enterpriseSelfTest-
Fail(2)
devLastTrapString
(devHealthAndStatus.-
mib)
Unit has completed
(re)initialization and a hardware
failure was detected.
String:
‘Self test failed: $
s.’ ($s is the
contents of devSelfTestResult.)
enterpriseTest-
Start(5)
For physical interfaces and
frame relay links:
ifIndex (RFC 1573)
.0.0 (placeholder)
devLastTrapString
(devHealthAndStatus.-
mib
For virtual circuits (DLCIs):
devFrExtDlciIfIndex
(devFrExt.mib)
devFrExtDlciDlci
(devFrExt.mib)
devLastTrapString
(devHealthAndStatus.-
mib
At least one test has been started
on an interface or virtual circuit.
String:
‘$testString test started on
$ifString.’ (e.g., ‘DTE Loopback
test started on Sync Data Port
S01P1.’)
enterpriseTest-
Stop(105)
All tests have been halted on an
interface or virtual circuit.
String:
‘$testString test stopped on
$ifString.’ (e.g., ‘Disruptive PVC
Loopback test stopped on DLCI
100 of Sync Data Port S01P1
frame relay.’)
Table B-7.
enterprise-Specific Traps and Variable-Bindings (3 of 3)
Trap
Variable-Bindings
Possible Cause
Summary of Contents for 9126
Page 150: ...4 Configuration Options 4 106 September 2002 9128 A2 GB20 80 ...
Page 182: ...6 Security and Logins 6 16 September 2002 9128 A2 GB20 80 ...
Page 264: ...7 Operation and Maintenance 7 82 September 2002 9128 A2 GB20 80 ...
Page 348: ...A Menu Hierarchy A 4 September 2002 9128 A2 GB20 80 ...
Page 440: ...E Connectors Cables and Pin Assignments E 18 September 2002 9128 A2 GB20 80 ...