C. Router CLI Commands, Codes, and Designations
C-10
September
2002
9128-A2-GB20-80
[
no
]
bridge-group
bridge-group
Minimum Access Level: Administrator
Command Mode: config-if, config-subif
Allows a user to apply or remove a set of bridge group parameters to/from an interface or
sub-interface. When a set of bridge group parameters is applied or removed at the
interface level, the command also applies to all sub-interfaces on the interface.
Example:
no bridge-group
NOTE: If the bridge group is only required on specific sub-interfaces, remove the
bridge group from an interface and apply it at the sub-interface level.
bridge-group – Valid bridge group number 1 is applied to all interfaces by default. Any
sub-interfaces created on interfaces where the bridge group is applied inherit the bridge
group.
[
no
]
bridge-group
bridge-group
{
input-type-list
in-access-list-200num
|
output-type-list
out-access-list-200num
}
Minimum Access Level: Administrator
Command Mode: config-if
Allows a user to specify or remove an input or output Ethernet type code filter for an
interface. No bridge group filters are applied to interfaces by default.
Example:
bridge-group 1 input-type-list 8069
NOTE: The order in which access-list filters are entered affects the order in which the
filters are applied. Each filter is applied in succession until all filters have been applied.
If no conditions match, a frame is discarded.
bridge-group – Valid bridge group number 1 is applied to all interfaces by default. Any
sub-interfaces created on interfaces where the bridge group is applied inherit the bridge
group.
input-type-list – Specify the filter applied to incoming Ethernet packets by type code.
Refer to
Table C-14, Ethernet Type Codes (Hex)
.
in-access-list-200num – The input type access list valid range for protocol type-code
access lists: 200 – 299.
output-type-list – Specify the filter applied to outgoing Ethernet packets by type code.
Refer to
Table C-14, Ethernet Type Codes (Hex)
, Ethernet Type Codes (Hex).
out-access-list-200num – The output type access list number valid range for protocol
type-code access lists: 200– 299.
Table C-6.
Bridge Commands (2 of 2)
Summary of Contents for 9126
Page 150: ...4 Configuration Options 4 106 September 2002 9128 A2 GB20 80 ...
Page 182: ...6 Security and Logins 6 16 September 2002 9128 A2 GB20 80 ...
Page 264: ...7 Operation and Maintenance 7 82 September 2002 9128 A2 GB20 80 ...
Page 348: ...A Menu Hierarchy A 4 September 2002 9128 A2 GB20 80 ...
Page 440: ...E Connectors Cables and Pin Assignments E 18 September 2002 9128 A2 GB20 80 ...