Displaying System Information
7-5
9161-A2-GH30-40
April 1999
View this field . . .
To find the . . .
For the FXO Voice APM (Cont’d)
T-R Receive
Status of what the attached device is doing with the Tip
and Ring leads of the FXO port.
RbTo. Attached device has battery applied to the
Ring lead and the Tip lead is opened
RbTg. Attached device has battery applied to the
Ring lead and the Tip lead is grounded
TbRg. Attached device has battery applied to the Tip
lead and the Ring lead is grounded
Ring. Attached device is applying Ringing voltage
between Tip and Ring
ToRo. Attached device has both Tip and Ring leads
open.
TgRo. Attached device has the Tip lead grounded
and the Ring lead open.
TgR*. Attached device has the Tip lead grounded
and the Ring lead state is unknown.
ToR*. Attached device has the Tip lead open and the
Ring lead state is unknown.
RoT*. Attached device has the Ring lead open and
the Tip lead state is unknown.
Trunk Cond CGA
Displays the status of trunk conditioning (On during
CGA, Off for no CGA).
Summary of Contents for 9161 Single T1
Page 1: ...MODEL 916x 926x T1 ACCESS MUX TECHNICAL REFERENCE Document No 9161 A2 GH30 40 April 1999...
Page 34: ...Management and Control 2 6 9161 A2 GH30 40 April 1999 This page intentionally left blank...
Page 54: ...User Interface 4 10 9161 A2 GH30 40 April 1999 This page intentionally left blank...
Page 92: ...Setting Up 5 38 9161 A2 GH30 40 April 1999 Example Channel Allocation...
Page 142: ...Security 6 10 9161 A2 GH30 40 April 1999 This page intentionally left blank...
Page 252: ...IP Addressing B 8 9161 A2 GH30 40 April 1999 This page intentionally left blank...