Setting Up
5-12
9161-A2-GH30-40
April 1999
Table 5-1.
Network Interface Options (6 of 7)
Alarm Indication Signal (AIS) Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when an alarm indication signal
condition is detected on the network interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Yellow Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when a yellow alarm condition is
detected on the network interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Excessive Error Rate (EER) Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when an excessive error rate
condition is detected on the network interface.
Excessive Error Rate only appears if Line Framing Format is set to ESF.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Summary of Contents for 9161 Single T1
Page 1: ...MODEL 916x 926x T1 ACCESS MUX TECHNICAL REFERENCE Document No 9161 A2 GH30 40 April 1999...
Page 34: ...Management and Control 2 6 9161 A2 GH30 40 April 1999 This page intentionally left blank...
Page 54: ...User Interface 4 10 9161 A2 GH30 40 April 1999 This page intentionally left blank...
Page 92: ...Setting Up 5 38 9161 A2 GH30 40 April 1999 Example Channel Allocation...
Page 142: ...Security 6 10 9161 A2 GH30 40 April 1999 This page intentionally left blank...
Page 252: ...IP Addressing B 8 9161 A2 GH30 40 April 1999 This page intentionally left blank...