MIB Descriptions
B-19
9161-A2-GH30-20
September 1997
Object
Setting/Contents
Description
dsx1SendCode
(dsx1ConfigEntry 7 )
Specifies the test patterns/
codes being sent over the
Network and DSX-1 T1
interface.
The dsx1SendNocode(1)
test is the only test
supported on the DSX-1
Drop/Insert T1 interface.
Supports only the following
values:
dsx1SendNocode(1) – Stops
an active “send pattern” test
on the interface. This is the
only value supported by the
DSX-1 T1 interface.
dsx1SendLineCode(2) – The
Network T1 interface is
sending a Remote Line
Loopback LLBUP code. The
code is sent for 10 seconds.
dsx1SendResetCode(4) –
The Network T1 interface is
sending a Remote Line
Loopback LLPDN code. The
code is sent for 10 seconds.
dsx1SendQRS(5) – The
Network T1 interface is
sending a QRSS test pattern.
The pattern is sent until the
test is halted (i.e., setting to
dsx1SendNocode).
dsx1Send511Pattern(6) –
The Network T1 interface is
sending a 511 test pattern.
The pattern is sent until the
test is halted (i.e., setting to
dsx1SendNocode).
dsx1Send3in24Pattern(7) –
The Network T1 interface is
sending a 3-in-24 test pattern.
The pattern is sent until the
test is halted (i.e., setting to
dsx1SendNocode).
dsx1SendOtherTestPattern
(8) – The Network T1 interface
is sending a test pattern other
than those listed above.
Supported as read-only.
dsx1CircuitIdentifier
(dsx1ConfigEntry 8 )
Supported on the network
T1 interface only.
Displays string set on network T1
interface option screen, the