MIB Descriptions
B-29
9161-A2-GH30-20
September 1997
Input Signal Table
The Input Signal Table contains entries for the input signals that can be detected
by the unit for each of the synchronous data ports. The objects in the following
table are supported. Clarification for objects contained in this table as it applies to
the unit is provided below.
Object
Description
Setting/Contents
rs232InSigName
(rs232InSigEntry 2 )
Contains the ID of a
hardware input signal.
Supports only the following values:
rts(1) – Request To Send
dtr(4) – Data Terminal Ready
rs232InSigState
(rs232InSigEntry 3 )
Contains the current signal
state.
Supports only the following values:
on(2) – The signal is asserted
off(3) – The signal is deasserted
Output Signal Table
The Output Signal Table contains entries for the output signals that can be
asserted by the unit for each of the synchronous data ports. The objects in the
following table are supported. Clarification for objects contained in this table as it
applies to the unit is provided below.
Object
Description
Setting/Contents
rs232OutSigName
(rs232OutSigEntry 2 )
Contains the ID of a
hardware output signal.
Supports only the following
values:
cts(2) – Clear To Send
dsr(3) – Data Set Ready
dcd(6) – Received Line Signal
Detect
rs232OutSigState
(rs232OutSigEntry 3 )
Contains the current signal
state.
Supports only the following
values:
on(2) – The signal is asserted
off(3) – The signal is
deasserted
rs232OutSigState
(rs232OutSigEntry 4)
The number of times that
the signal has changed
state.
Object increments everytime that
the signal is sampled (every
100 milliseconds) and the state
has changed from the previous
sample.