SNMP Cross-Reference
D-12
9161-A2-GH30-20
September 1997
Table D-1.
SNMP MIB to User Interface Command Cross-Reference (12 of 13)
User Interface Command
SNMP MIB Object
main/config/cross_connect:
DSX-1-to-Network Assignments
Network to Network Assignments
Voice Port Assignments
Sync Data Port Assignments
Clear DSX-1 Time Slots
Clear Network Interface Time Slots
Clear Slot
nn
Fully supported by the device cross-connect MIB objects using:
devDs1FracTable
devDs1FracTable
devDs1FracTable
devSyncDataPortAssignTable
Use devDs1FracTable to clear all time slots
Use devDs1FracTable to clear all time slots
Use devDs1FracTable to clear all time slots
main/config/system:
Test Timeout
Test Duration
Primary Clock Source
Secondary Clock Source
Set/Read:
devConfigTestTimeout
devConfigTestDuration
devConfigClockSrcTable (read only)
devConfigClockSrcTable (read only)
main/config/user/com:
COM Port
Port Usage
Port Type
Data Rate
Character Length
Parity
Stop Bits
Ignore Control Leads
Clock Source
Set/Read:
devPortUsage to
netlink, alarm, or terminal
See the Asynchronous/Synchronous Port Table for the entry
rs232PortInSpeed or rs232PortOutSpeed for the port
rs232AsyncPortBits for the port
rs232AsyncPortParity for the port
rs232AsyncPortStopBits for the port
rs232PortInFlowType for the port
rs232SyncPortClockSource to
internal or external
main/config/management/security:
IP Address
Access Type
Set/Read:
devSecurityMgrIpAddress
devSecurityMgrAccess to
read or readWrite
main/config/management/trap:
IP Address
Destination
General Traps
Enterprise-Specific Traps
Link Traps
Link Traps Interfaces
Set/Read:
devTrapMgrIpAddress
devTrapMgrDestination
devConfigTrapEnable
devConfigTrapEnable
devConfigTrapEnable
ifLinkUpDownTrapEnable for the interface
main/control/device_name:
System Name
System Contact
System Location
Set/Read:
sysName object from the System group
sysContact object from the System group
sysLocation object from the System group