Setting Up
4-12
9161-A2-GH30-20
September 1997
Table 4-1.
Network Interface Options (6 of 7)
Alarm Indication Signal (AIS) Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when an alarm indication signal
condition is detected on the network interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Yellow Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when a yellow alarm condition is
detected on the network interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Excessive Error Rate (EER) Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when an excessive error rate
condition is detected on the network interface.
Excessive Error Rate only appears if Line Framing Format is set to ESF.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.