2–
OK
OK
ALM
TST
BKP
SIG
OOF
ALM
SIG
OOF
ALM
1–
OK
9161
IN
OUT
IN
OUT
IN
OUT
IN
OUT
NET
DSX
NET
MON
DSX MON
NETWORK
DSX
POR
T
496-15051
Test
Jacks
LEDs
Troubleshooting
9-2
9161-A2-GH30-40
April 1999
T1 NAM LEDs
General Status LEDs
Label Indication
Color
What It Means
OK
Power and
Operational
Status
Green
ON
– NAM has power and is operational.
OFF – NAM is in a power-up self-test, or there is a
failure.
CYCLING – The unit is in Minimum mode. Requires an
FTP download.
ALM
System
Failure/
Self-Test
Red
ON
– NAM has just been reset, or an error or fault
has been detected.
OFF – No failures have been detected.
TST
Test Mode
Yellow
ON
– Loopback or test pattern in progress, initiated
locally, remotely, or from the network.
OFF – No tests are active.
BKP
Backup
Yellow
Not supported in this release. Remains off except during
a Lamp Test.