Troubleshooting
9-14
9161-A2-GH30-40
April 1999
Table 9-1.
ASCII Alarm Messages (2 of 5)
Message
Priority
What To Do
What It Indicates
month/day/year
hours:minutes:seconds –
Continuous Loss Of Signal
(LOS) condition detected at
the Network 1/Network 2
Interface or at DSX-1
Interface in slot
ss port p.
LOS condition
detected.
1. Check the cable to
the Network/DSX-1
interface.
2. Contact network
provider.
2 (Net)
3 (DSX-1)
month/day/year
hours:minutes:seconds –
Alarm Cleared for Loss Of
Signal (LOS) condition at
the Network 1/Network 2
Interface or at the DSX-1
Interface in slot
ss port p.
Alarm condition no
longer exists.
No action needed.
month/day/year
hours:minutes:seconds –
Continuous Out Of Frame
(OOF) detected at the
Network 1/Network 2
Interface or at DSX-1
Interface in slot
ss port p.
An out-of-frame
condition is detected
at the specified
Network or DSX-1
interface.
1. Ensure that the line
framing format
configuration option
setting matches the
setting of the
equipment (DSX-1)
or network (Net).
2. Contact network
provider.
4 (Net)
5 (DSX-1)
month/day/year
hours:minutes:seconds –
Alarm Cleared for Out of
Frame (OOF) condition at
the Network 1/Network 2
Interface or at the DSX-1
Interface in slot
ss port p.
Alarm condition no
longer exists.
No action needed.
month/day/year
hours:minutes:seconds –
Continuous Out of Frame
(OOF) condition at
synchronous data port in
slot
ss port p.
A continuous
out-of-frame condition
occurred on the
synchronous data port
for the identified slot
and port.
1. Ensure that EDL is
enabled on the
far-end port.
2. There is a network
problem with the
fractional portion of
the link carrying this
port’s data. Contact
network provider.
13
month/day/year
hours:minutes:seconds –
Alarm Cleared for Out Of
Frame (OOF) condition at
synchronous data port in
slot
ss port p.
Alarm condition no
longer exists.
No action needed.
month/day/year
hours:minutes:seconds –
A DDS Network Failure
code has been received at
OCU-DP port in slot
ss
port
p.
A DDS network failure
is being detected on
the specified OCU-DP
port.
Contact the DDS
service provider.
19
Summary of Contents for 9261
Page 1: ...MODEL 916x 926x T1 ACCESS MUX TECHNICAL REFERENCE Document No 9161 A2 GH30 40 April 1999 ...
Page 34: ...Management and Control 2 6 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Page 54: ...User Interface 4 10 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Page 92: ...Setting Up 5 38 9161 A2 GH30 40 April 1999 Example Channel Allocation ...
Page 142: ...Security 6 10 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Page 252: ...IP Addressing B 8 9161 A2 GH30 40 April 1999 This page intentionally left blank ...