Setting Up
5-22
9161-A2-GH30-40
April 1999
Table 5-3.
Synchronous Data Port Options (6 of 7)
Near-End Performance Statistics
Possible Settings: Disable, Maintain, Send, Both
Default Setting: Disable
Specifies whether the T1 access unit maintains near-end performance statistics and
sends Performance Report Messages (PRMs) for the synchronous data port.
Near-End Performance Statistics does not appear if:
– EDL is set to Disable.
– Management Link is set to FDL.
NOTE:
If the local T1 access unit is configured to send near-end performance
statistics, then the remote T1 access unit must be configured to maintain
far-end performance statistics.
Disable – Does not maintain near-end performance statistics or send PRMs.
Maintain – Maintain near-end performance statistics for the port.
Send – Send PRMs over the port’s EDL every second. Each PRM contains the
performance statistics for the previous 4 seconds.
Both – Maintain near-end performance statistics and send PRMs over the port’s EDL.
Far-End Performance Statistics
Possible Settings: Disable, Maintain
Default Setting: Disable
Specifies whether the T1 access unit maintains far-end performance statistics and
sends Performance Report Messages (PRMs) for the synchronous data port.
Far-End Performance Statistics does not appear if:
– EDL is set to Disable.
– Management Link is set to FDL.
NOTE:
If the local T1 access unit is configured to maintain far-end performance
statistics, then the remote T1 access unit must be configured to send
near-end performance statistics.
Disable – Does not monitor the port’s EDL for PRMs or maintain far-end performance
statistics.
Maintain – Monitors the port’s EDL for PRMs and maintains far-end performance
statistics.
Out of Frame (OOF) Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Out of Frame (OOF). Specifies whether an alarm is generated when an out-of-frame
condition is detected on the synchronous data port.
Out of Frame does not appear if:
– Embedded Data Link is set to Disable.
– Management Link is set to FDL on the Network Interface Options screen (see
Table 5-1
).
Enable – Generates an alarm.
Disable – Does not generate an alarm.
Summary of Contents for 9261
Page 1: ...MODEL 916x 926x T1 ACCESS MUX TECHNICAL REFERENCE Document No 9161 A2 GH30 40 April 1999 ...
Page 34: ...Management and Control 2 6 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Page 54: ...User Interface 4 10 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Page 92: ...Setting Up 5 38 9161 A2 GH30 40 April 1999 Example Channel Allocation ...
Page 142: ...Security 6 10 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Page 252: ...IP Addressing B 8 9161 A2 GH30 40 April 1999 This page intentionally left blank ...