Operation
3-9
3170-A2-GB20-20
December 1996
To change the customer identification (CID),
1. Press the
key on the top-level menu to bring
the Ctrl branch onto the front panel LCD.
F1
DSU E1 CEPT
Stat
Test
Cnfig
F2
F3
2. Press F3 to select Ctrl from the top-level menu
screen.
F1
DSU E1 CEPT
Test
Cnfig
Ctrl
F2
F3
3. Press the
key on the Control screen until the
CID selection appears on the front panel LCD.
F1
Control:
Rel
LED
ClrReg
F2
F3
4. Select CID.
F1
Control:
Reset
CID
DL
F2
F3
5. Use the
and
keys to position the cursor
under the desired character. You must enter a
character before the
moves the cursor to the
next space to the right.
F1
CustID:xxxxxxxx
Up
Down
Save
F2
F3
6. Enter the desired ID. Press F1 (Up) and F2
(Down) to scroll up and down through the valid
characters/numbers for the customer ID. Valid
characters are 0 through 9, #, -, ., /, A to Z, and
blank space. Press F3 (Save) to save the ID.
F1
CustID:xxxxxxxx
Up
Down
Save
F2