Setting the IP Address
The IP address of the Management Module must be set before the BitStorm 4800
can be remotely managed.
Procedure
To set the IP address of the Management Module:
1. At the
IAC#
prompt, type:
configure management address
address mask gateway
Where:
—
address
is the IP address to be assigned to the Management Module
—
mask
is the IP subnet mask for the specified address
—
gateway
is the default gateway IP address
For example:
conf man addr 135.26.10.37 255.255.255.0 135.26.10.254
2. Press Enter. The prompt changes to
IAC#!
to show that the configuration
change has yet to be saved.
3. Type
save
and press Enter.
4. To verify that the address has been set, type:
show management ip