background image

4

November 1996

3980-A2-GZ41-10

Equipment Warranty and
Support

Technical Support

Contact your sales or service representative directly for

any help needed. For additional information concerning
warranty, sales, service, repair, installation, documentation
or training, use one of the following methods:

Via the Internet: Visit the Paradyne World Wide
Web site at http://www.paradyne.com

Via Telephone: Call our automated call system to
receive current information via fax or to speak with
a company representative.

— Within the U.S.A., call 1-800-870-2221

— International, call 813-530-2340

Equipment Service

After opening the modem’s package, check for damage

and verify that the following items are present:

3811Plus modem

Rear connector plate with DB-25-P edge card
connector

Examine the equipment carefully upon arrival. If there

is an obvious defect or you experience trouble please
contact your sales or service representative (as
appropriate) for repair or warranty information. If the
product needs to be returned to the company service
center for repair, contact them directly for return
instructions using one of the following methods:

Via the Internet: Visit the Paradyne World Wide
Web site at http://www.paradyne.com

Via Telephone: Call our automated call system to
receive current information via fax or to speak with
a company representative.

— Within the U.S.A., call 1-800-870-2221

— International, call 813-530-2340

Installation

Customer-Supplied Equipment

The 3811Plus modem (see Figure 1) is designed for

installation in a COMSPHERE 3000 Series Carrier which
supplies operating power and the dial-line and/or
leased-line network connections. For power, dial-line,
leased-line, Network Interface Module (NIM), and
network management cabling information, refer to the
COMSPHERE 3000 Series Carrier Installation Manual
(Document Number 3000-A2-GA31).

In addition to the carrier, the following

customer-supplied equipment may be required for the
installation of a 3811Plus modem:

A Shared Diagnostic Unit (SDU, required for
network management applications and multiple
carriers).

A Shared Diagnostic Control Panel (SDCP).

One 6-position to 6-position modular cord (required
for network management applications).

Two 50-pin mass termination cables, one NIM for
modems installed in Slots 1–8, and one NIM for
modems installed in Slots 9–16 (required for
dial-line applications).

One of the following dial or leased network
interfaces:

— 50-pin to modular cable (RJ11C) for dial

permissive applications

— 50-pin to modular cable (JM8) for leased line

applications

An RS-232 DTE cable with a DB25 connector at
one end and a connector appropriate to your DTE at
the other end.

If the modem is to be managed by a network

management system, an SDU must be supplied and
properly connected to the network management controller.
For proper network management connection to the SDU,
refer to the appropriate network management system
user’s guide.

Summary of Contents for COMSPHERE 3811Plus

Page 1: ...E CHANGE Please note that the area code for Paradyne Corporation in Largo Florida has changed from 813 to 727 For any Paradyne telephone number that appears in this manual with an 813 area code dial 727 instead ...

Page 2: ...he equipment is to be used with telecommunications circuits take the following precautions Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when inst...

Page 3: ...page or on the first page of the transmission the date and time it is sent and an identification of the business or other entity or other individual sending the message and the telephone number of such business or other entity or individual In order to program this information follow the steps outlined in the manual supplied with your fax software Notice to Users of the Canadian Public Switched Te...

Page 4: ...and circuit and ii cable or wiring complying with a code of practice for the installation of equipment covered by this part of BS 6328 or such other requirements as may be applicable This modem is suitable for connection to BT circuits with signalling at a nominal frequency of 2280 Hz and may be connected to multipoint or point to point circuits The apparatus does not require signalling or otherwi...

Page 5: ...he U S A call 1 800 870 2221 International call 813 530 2340 Installation Customer Supplied Equipment The 3811Plus modem see Figure 1 is designed for installation in a COMSPHERE 3000 Series Carrier which supplies operating power and the dial line and or leased line network connections For power dial line leased line Network Interface Module NIM and network management cabling information refer to t...

Page 6: ...R LSD 103 104 105 106 107 108 109 Pwr Alrm Test Dial RI Busy Serv SQ Status Front Panel 3811Plus 142 125 Spkr Faceplate EIA232 V 24 Edge Card Connector EIA232 V 24 Connector Unused V 35 3600 3500 RS366A V 25 3800 EIA232 V 24 Rear Connector Plate Figure 1 3811Plus Modem ...

Page 7: ... slot position as that intended for the modem 496 14906 V 35 3600 3500 RS366A V 25 3800 EIA232 V 24 25 Pin DTE Connectors P21 Loosely fasten the plate This allows for slight adjustments later when installing the modem CAUTION Always use a ground strap when handling a modem Always store a 3811Plus modem in an antistatic bag when it is removed from the carrier 495 14797 2 At the front of the carrier...

Page 8: ...modem Perform the following steps Select SDU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 COMSPHERE 3000 Select Key Status Indicators Carrier Slots 1 16 F1 F2 F3 OK Alarm BckUp Test EC Keypad LCD Display 496 12348a 03 Procedure 1 Press the Select key on the SDCP The cursor appears in the two digit slot selection entry 2 Press the key to position the cursor on the two digit carrier selection entry 3 Pres...

Page 9: ...ctory preset configurations 5 Press the key until the appropriate factory preset appears on the LCD and press the corresponding function key to select your choice If you select Sync Leased a new prompt asks you to select Answer Mode F1 or Originate Mode F3 Press the appropriate key 6 Choose Function now appears and displays the Edit and Save functions 7 Press the F3 key Save The LCD displays Sav E...

Page 10: ...ifferent factory preset configuration Menu Structure The menu tree accessible from the SDCP contains the following branches Call Setup Used to dial disconnect and answer telephone calls as well as store up to 10 telephone numbers in directory locations Status Used to monitor the current status of the VF line and DTE interface as well as view the identity of the modem Test Used to begin and end var...

Page 11: ...aler Type DialTone Detect Blind Dial Paus BusyTone Detect Pause Time NoAnswer Timout Fast Disconnect Long Space Disc No Carrier Disc No Data Disc NoDataDiscTrig Auto Make Busy MakeBusyViaDTR DTR Auto Redial MI MIC Dialing Dial_Line Modulation Dial Line Rate Automode Autorate Dial TX Level V22b Guard Tone Train Time Asymmetric Rate Fall Fwd Delay 496 14528a 02 Displays current status of modem along...

Page 12: ...MS_Call_Msgs NMS DTR Alarm NetworkPosition CellulrRJ11Adpt Security EntryWait_Time VF_Prompt_Type DTE_PW_Tries DTE_PW_TermChar DTE_PW_BkSpChar Get_User_ID NMS_Reporting Answer_Secur Originate_Secur 496 14528b 02 Does not appear if configured for Synchronous mode Only appears if Sync_Leased factory template is selected Some choices within this group may not appear depending upon how previous config...

Page 13: ...rim data blckd ExitRem appears instead of Remote when using Remote Mode Does not appear in Remote Mode Rem_Digital_Loop Loc_Digital_Loop and Pattern appear if the secondary channel is used Security Set_Access_Ctrl Admin Password Reset_Security EditPassWdTable Set_Answer_Sec Set_Orig_Secur Set_Admin_PsWd 496 14528c 02 from previous page Install ...

Reviews: