Ringer Equivalence Number

The Ringer Equivalence Number (REN) is a customer guide indicating approximately
the maximum number of items of apparatus that should be connected simultaneously to
the telephone line. The sum of the RENs should not exceed four. This value includes
any BT-provided instrument which may be assumed to have a REN of 1 unless marked
otherwise. The REN of this modem is 1.

Connection to Leased Lines

If any other apparatus, including cable or wiring, is connected between the apparatus
and the point of connection to any speechband circuit, then all that other apparatus
shall comply with the following:

1. The overall transmission characteristics of all that other apparatus shall be such as

to introduce no material effect upon the electrical conditions presented to one
another by the apparatus and the speechband circuit; and

2. All that other apparatus shall comprise only:

(i) apparatus approved for the purpose of connection between the apparatus and a
speechband circuit; and

(ii) cable or wiring complying with a code of practice for the installation of
equipment covered by this part of BS 6328 or such other requirements as may be
applicable.

This modem is suitable for connection to BT circuits with signalling at a nominal
frequency of 2280 Hz and may be connected to multipoint or point to point circuits. The
apparatus does not require signalling or otherwise use the frequency range 0 –200 Hz.

No dc interaction is intended between the modem and the telephone network.

This apparatus may be directly connected to a speechband circuit or connected to a
relevant branch system for speechband circuits.

All European Countries

Safety Notice

Interconnection circuits between this modem and any other equipment should be such
that the equipment continues to comply with the requirements of EN41003 for TNV
(Telephone Network Voltage) circuits and EN60950 for SELV (Safety Extra Low
Voltage) circuits after making connection between circuits.

Summary of Contents for COMSPHERE 3821PLUS

Page 1: ...COMSPHERE 3821Plus MODEM QUICK REFERENCE Document No 3821 A2 GL10 00...

Page 2: ...and issued as a new release to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additio...

Page 3: ...PHERE 3821Plus Modem User s Guide To request a paper copy of a Paradyne document Within the U S A call 1 800 PARADYNE 1 800 727 2396 Outside the U S A call 1 727 530 8623 3821Plus Installation A typic...

Page 4: ...nd its power supply can be found in the COMSPHERE 3000 Series Carrier Installation Manual Document Number 3000 A2 GA31 Install the NIM A NIM can be installed on the left or right side of the back of t...

Page 5: ...the 50 pin connector in the middle of the NIM Connect the other end to the dial or leased line interface This may be an RJ11 gang box or a 66A punchdown block 495 14798 NETWORK INTERFACE CABLE P21 or...

Page 6: ...ce assembly it must be mounted on the same side you installed the NIM Procedure 1 Feed the eight tabs at the bottom of the DTE interface assembly into the slots on the left or right side of the carrie...

Page 7: ...til the back edge of the card seats in the socket of the DTE interface assembly 495 14797 Procedure 1 Turn the circuit pack lock until it is vertical locking the 3821Plus card in place 2 When all card...

Page 8: ...instructions to the modem A dumb asynchronous terminal however does not require this software since it can directly send AT commands The 3821Plus can be used with any major communications software Re...

Page 9: ...inate mode 5 Press the key until the appropriate factory preset appears on the LCD and press the corresponding function key to select your choice 6 Choose Function appears and displays the Edit and Sa...

Page 10: ...may have lost AT command control To regain AT command control select via the SDCP the Async Dial factory preset configuration To change a factory template using AT commands perform the following step...

Page 11: ...st connected to a 3821Plus card using the Select key on the SDCP F1 Idle 33 6 MDMA mdmb mdmc F2 F3 Press F1 F2 or F3 to connect the SDCP to modem A B or C respectively The connected modem appears on t...

Page 12: ...Modem Status MDMA mdmb mdmc Call_Setup Status Branch The Status branch of the Top Level menu allows you to view the current status of the dial or leased line connection the DTE interface and the ident...

Page 13: ...ommunication problems such as periodic character loss random errors or constant format errors By the process of elimination you can usually isolate the fault in your system Abort Self Loc_Analog_Loop...

Page 14: ...Operating Active Saved Customer1 Customer2 Factory Async_Dial Sync_Dial Sync_Leased UNIX_Dial Choose Mode Answer Originate Ld EditArea frm Edit Save Choose Function Active Saved Customer1 Customer2 DT...

Page 15: ...ervLine Download Code 495 14846 Call_Setup Test Security Configure Remote Status Modem Status MDMA mdmb mdmc Control Remote Branch The Remote Access feature of 3821Plus modems allows you to change con...

Page 16: ...Control and Reset Security 495 14847 Set_Access_Ctrl Admin Password Reset_Security EditPassWdTable Set_Answer_Sec Set_Admin_PsWd Set_Orig_Secur Set_CallBack_Sec Security Call_Setup Control Test Config...

Page 17: ...o Result Codes section Q1 Disables result codes Q2 Enables originate modem to send result codes to the DTE Required for most UNIX applications Sn Displays value of S Register where n is the register n...

Page 18: ...ar PSTN if ETC installed Gn V 22bis Guard Tone G0 Disables guard tone G1 Sets guard tone to 550 Hz G2 Sets guard tone to 1800 Hz AT COMMANDS continued In Dial Transmit Level I10 10 dBm I11 11 dBm I32...

Page 19: ...er An Maximum Frame Size A0 64 A1 128 A2 192 A3 256 A4 32 A5 16 AT COMMANDS continued Cn Error Control Negotiate Buffer C0 Data is not buffered during handshaking sequence C1 Data is buffered up to 4...

Page 20: ...sthrough X1 Enables XON XOFF Passthrough An Sets error control fallback character n to an ASCII value from 0 to 127 Bn Sets modulation to V 34 and VF rate to n 300 1200 or 2400 to 33600 in increments...

Page 21: ...32bis 4 7200 V 32bis 5 4800 V 32bis 6 2400 V 22bis 7 1200 V 22 8 1200 212A 10 0 300 V 21 11 0 300 103J 20 19200 V 32terbo 21 16800 V 32terbo 27 33600 V 34 28 31200 V 34 29 28800 V 34 30 26400 V 34 31...

Page 22: ...anagement Address 255 0 255 001 256 S76 Dial Autorate 0 0 Enable 1 Disable 2 Start at 4800 3 Start at 9600 S77 DTR Alarm Reporting 0 0 Disable 1 Enable S78 Dial Automode 0 0 Enable 1 Disable 2 System8...

Page 23: ...the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 7 A rare phenomenon can create a voltage potential be...

Page 24: ...uipment designed for use within certain voltage limits as amended by Directive 93 68 EEC Directive 89 336 EEC Council Directive of 3 May 1989 on the approximation of the laws of the Member States rela...

Page 25: ...ustomer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary 5 The telephone company may make changes in its facilities equipment...

Page 26: ...an acceptable method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone exte...

Page 27: ...tus shall comprise only i apparatus approved for the purpose of connection between the apparatus and a speechband circuit and ii cable or wiring complying with a code of practice for the installation...

Page 28: ...g to the instruction manual Restrictions Due to JATE Japan Approvals Institute for Telecommunications Equipment regulations only 3 attempts to dial a number are permitted in a 3 minute period If a fou...

Reviews: