background image

TM

 1   

Universal Power Supply
Installation Instructions

Document Number 9000-A2-GN21-20

February 1999

The Universal power supply is only installed in a FrameSaver

 or FrameSaver SLV

access unit and is intended for international markets.

Package Contents

The shipping box contains a desktop (in-line) power transformer, with an attached cord
and ferrite choke, for connecting to the access unit, and a power cord.

Before You Begin

Make sure you have:

A dedicated, grounded power outlet within 6 feet of the access unit that is
protected by a circuit breaker.

A clean, well-lit, and ventilated site that is free from environmental extremes.

One or two feet of clearance for cable connections.

Technical Specifications

Specification

Criteria

Power

Input

Output

100–240 Vac, 50/60 Hz, 0.7A

12 Vdc,  2.5A, 1.0A minimum

Power Consumption and
Dissipation

4.8 watts,  100 mA at 100 Vac 
Result: 16.38 Btu per hour

5.0 watts, 90 mA at 120 Vac
Result: 17.06 Btu per hour

5.6 watts, 60 mA at 240 Vac
Result: 19.11 Btu per hour