TM
1
Universal Power Supply
Installation Instructions
Document Number 9000-A2-GN21-20
February 1999
The Universal power supply is only installed in a FrameSaver
or FrameSaver SLV
access unit and is intended for international markets.
Package Contents
The shipping box contains a desktop (in-line) power transformer, with an attached cord
and ferrite choke, for connecting to the access unit, and a power cord.
Before You Begin
Make sure you have:
A dedicated, grounded power outlet within 6 feet of the access unit that is
protected by a circuit breaker.
A clean, well-lit, and ventilated site that is free from environmental extremes.
One or two feet of clearance for cable connections.
Technical Specifications
Specification
Criteria
Power
Input
Output
100–240 Vac, 50/60 Hz, 0.7A
12 Vdc, 2.5A, 1.0A minimum
Power Consumption and
Dissipation
4.8 watts, 100 mA at 100 Vac
Result: 16.38 Btu per hour
5.0 watts, 90 mA at 120 Vac
Result: 17.06 Btu per hour
5.6 watts, 60 mA at 240 Vac
Result: 19.11 Btu per hour