Maintenance and Troubleshooting
5-10
9621-A2-GB20-30
August 1997
Message
What To Do
What It Indicates
Invalid – Phone
number must be at
least 7 digits
Fewer than seven numbers
were entered for the phone
number associated with the
BRI Service Profile ID
(SPID).
Enter additional number(s),
Tab to the Clear field, and
re-enter the BRI phone number.
Invalid – SPID must
be at least 3 digits
Fewer than three numbers
were entered for the BRI
Service Profile ID (SPID)
configuration option.
Enter additional number(s),
Tab to the Clear field, and
re-enter the SPID.
Invalid Test
Combination
A conflicting loopback or
pattern test was in progress
when Start was selected to
start another test, or was
active on the same or
another interface when
Start was selected.
Wait until other test ends and
message clears.
Cancel all tests from the Test
screen ( Path: main/ test ).
Stop the test from the same
screen the test was started
from.
Limit of six Login IDs
reached
An attempt to enter a new
login ID was made, and the
limit of six login/password
combinations has been
reached.
1. Delete another login/password
combination.
2. Reenter the new login ID.
Limit of 40 Links
Reached
A management PVC is
being created and 40 links
already exist.
Do not create the link.
Delete another link, and try
again.
More than one DLCI is
defined for the port.
More than 1 compression
DLCI record has been
defined for the port, and
Bit Synchronous is set to
Enable.
1. Delete all but one DLCI record
for Port 1.
2. Select Bit Synchronous.
3. Enable.
More than six DLCIs
defined for the port.
More than 6 compression
DLCI records have been
defined for the port, and
Compression is set to
Enable.
Delete Port 1 DLCI records until
the number of records is 6 or
fewer.
Name Must be Unique
Name entered for a
management PVC has
been used previously.
Enter another 4-character name
for the logical/management link.