Maintenance and Troubleshooting
5-7
9621-A2-GB20-30
August 1997
Message
What To Do
What It Indicates
The Low Compression
Ratio condition for DLCI
Number [
DLCI number ]
is down on the Port 1
Interface.
The compression ratio
for the specified DLCI on
Port 1 has fallen below
the threshold that had
been configured for the
access unit identified.
Only appears when
compression has been
enabled.
If not a temporary condition:
Raise the Compression Ratio
Threshold from the ( Path:
main/configuration/edit/user/
com) for the access unit
identified.
Disable the Compression
Ratio Alarm.
Check the type of data being
compressed for realistic
compressibility.
Disable compression if data is
already compressed.
Alarm Cleared. The Low
Compression Ratio
condition for DLCI
Number [
DLCI number ]
is up on the Port 1
Interface.
Alarm condition no
longer exists.
—
A DBM Card Failure has
been detected.
A DBM Card Failure
condition has been
detected.
Call your service representative
for assistance.
Alarm Cleared for a DBM
Card Failure.
Alarm condition no
longer exists.
—
mm/dd/yy hh:mm:ss –
An ISDN Network Failure
has been detected
(active).
ISDN Network Failure
condition has been
detected at the specified
date (month/day/year)
and time
(hour:minute:second).
Check the network
connection.
Contact network provider.
mm/dd/yy hh:mm:ss –
Alarm Cleared for an
ISDN Network Failure.
Alarm condition no
longer exists.
—
The Frame Relay Logical
Link is down on the
[
DDS Network/ Port-1/
Port-2/BRI-B1 ] Interface.
Frame relay Link Status
has been enabled or
disabled.
Network has reported
that the frame relay Link
Status has changed; it
has been enabled or
disabled.
Verify that Link Status is
enabled on the access unit
identified.
Verify that LMI Personality is
set to User Side.
Check Service Log; counter
may have been reset.
Alarm Cleared. The
Frame Relay Logical Link
is up on the [
DDS
Network/ Port-1/ Port-2/
BRI-B1 ] Interface.
Alarm condition no
longer exists.
—