Configuration Options
4-19
9783-A2-GB20-00
July 2000
Configuring Circuit and DLCI Records
Circuit and DLCI records can be created and modified, and PVCs created based
on existing DLCIs, using the Network Circuit Records screen and the Data Ports
DLCI Records screen:
Main Menu
→
Configuration
→
Network
→
Circuit Records
Main Menu
→
Configuration
→
Data Port
→
DLCI Records
Table 4-9.
DLCI Record Options (1 of 3)
DLCI Number
Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.
Specifies the number for the DLCI in the DLCI record. The parameter determines which
DLCI record is used for transferring data on a particular frame relay interface. DLCI
numbers range from 0 to 1023. However, the numbers 0 to15 and 1008 to 1023 are
reserved. Entry of an invalid number results in the error message
Value Out of
Range (16 – 1007)
. If the DLCI number is part of a connection, this field is read-only.
NOTES: – If a DLCI number is not entered, the DLCI record is not created.
– The DLCI number entered must be unique for the interface.
– Changing settings for this configuration option causes the FrameSaver
unit to abort any active frame relay tests.
16 – 1007 – Specifies the DLCI number (inclusive).
VPI,VCI Number (VPI)
Possible Settings: 0 – 15
Default Setting: Initially blank; no default.
Specifies the VPI. Entry of an invalid number results in the error message
Value Out
of Range (0 – 15)
. The VPI/VCI must be unique on the ATM link.
Display Conditions – This option does not appear for the user data port.
0 – 15 – Specifies the VPI.
VPI,VCI Number (VCI)
Possible Settings: 32 – 255
Default Setting: Initially blank; no default.
Specifies the VCI. Entry of an invalid number results in the error message
Value Out
of Range (32 – 255)
. The VPI/VCI must be unique on the ATM link.
Display Conditions – This option does not appear for the user data port.
32 – 255 – Specifies the VCI.
Summary of Contents for FrameSaver DSL 9783 CSU/DSU
Page 1: ...FrameSaver DSL 9783 USER S GUIDE Document No 9783 A2 GB20 00 July 2000...
Page 24: ...About the FrameSaver DSL Unit 1 12 9783 A2 GB20 00 July 2000...
Page 134: ...Operation and Maintenance 6 36 9783 A2 GB20 00 July 2000...
Page 182: ...Menu Hierarchy A 4 9783 A2 GB20 00 July 2000 This page intentionally left blank...