12
Power-On Self-Test
When power is applied to the FrameSaver SLV 9520-ILM, it performs a series of internal
tests. The SYSTEM TST and SYSTEM OK LEDs are on during the power-on self-test.
When the test is complete, all LEDs light up for about five seconds, then assume their
assigned functions. After the test, if the test ran with no errors, the SYSTEM OK LED
stays on and the SYSTEM ALM (Alarm) LED turns off.
If the power-on self-test failed, a message describing the failure can be displayed on the
System and Test Status screen of the Asynchronous Terminal Interface. Use this menu
sequence to view the System and Test Status screen:
Main Menu
→
Status
→
System and Test Status
Configuration Using Configuration Edit/Display
The FrameSaver unit should operate using the default (factory-set) configuration
options, with exception to the changes specified in these installation instructions. Refer
to the following table for help in navigating through the menus.
Press the . . .
To . . .
Esc key
Go back one screen or menu level. To see a visual
representation of the menu levels, see
Menu Hierarchy
on
page 9.
Tab key, or
Up (
↑
), Down (
↓
),
Left (
←
) and Right (
→
)
Arrow keys
Move the cursor from one menu item to the next.
Enter or Return key
Complete the menu or option selection.
Spacebar
Display the next available setting when changing a
configuration option. All the available settings for an option
appears at the bottom of the screen.