14
Minimal Installation
A minimal configuration can be performed using the Easy Install screen. Once the unit is
installed and minimal configuration is completed, the NOC can complete and verify the
setup.
Procedure
1.
Select the Easy Install feature.
Main Menu
→
Easy Install
2.
Enter the Node IP Address and Subnet Mask.
3.
For management:
Set TS Access to DLCI, then select a DLCI on the network interface to be used as
the troubleshooting access link.
–
or –
Create a dedicated network management link. Select a DLCI when prompted. The
management link will be used by the NOC to access the unit.
4.
If the Ethernet port will be used, select the Ethernet Port Options Screen. Enable
the interface. Respond Yes to the prompt
Would you like to set the
Node's Default IP Destination to Ethernet?
and configure the
following:
—
Enter the IP address and subnet mask for the Ethernet interface.
—
Enter the Default Gateway Address (the IP Address that will be used for
packets without a route).
—
Press the ESC key to return to the Easy Install screen.
main/easy_install 9520-ILM
Device Name: Node A 12/13/2002 01:01
EASY INSTALL
Service Type Frame Relay
Node IP Address: 000.000.000.000 Clear
Node Subnet Mask: 000.000.000.000 Clear
TS Access: DLCI 980
Create a Dedicated Network Management Link
Ethernet Port Options Screen
Network 1 Line Build Out (LBO): Short
Port 1 Line Build Out (LBO): Short
---------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save