MTU-M Status and Performance Functions
5-4
7900-A2-GB20-00
March 1998
Viewing the Detailed Status of a specific xTU-C
To access the status of an individual termination unit configured as CO, type the
ID number of the termination unit at the For status, enter xtu id or ALL: prompt
and press Enter. The status of the selected termination unit appears as follows:
Menu path: Main
→
Status
→
(2-80)
(Screen 1 of 2)
Status Of HDSL Circuit #3
Major alarm .........
OFF
Minor alarm .........
OFF
Abnormal condition...
OFF
______________________________HTU–C___________ HTU-R_____
MTU-M poll state .....
In service
In service
Circuit state Loop A .
In service
In service
Circuit state Loop B .
In service
In service
Network input signal .
In service
N/A
DTR Signal ...........
Active
DSR Signal ...........
Active
S/N Ratio Loop A ....
42.0 dB
43.0 dB
S/N Ratio Loop B .....
42.5 dB
43.5 dB
Hit return to continue ...
The following table provides definitions of the fields contained on Screen 1 of the
Circuit Status screen:
Status
Function
MTU-M poll state
Indicates the MTU-M Polling status of the xTU-C/R pair
selected.
H
In service
H
Out of service
H
Poll MOS (maintenance out of service)
Circuit state Loop A
Indicates the communications status of Loop A.
H
In service
H
Out of service
H
N/A
Circuit state Loop B
(HDSL only)
Indicates the communications status of Loop B (HDSL only).
H
In service
H
Out of service
H
N/A
Summary of Contents for HOTWIRE 7900
Page 8: ...Contents iv 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 28: ...System Terminal Interface 4 6 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 72: ...Testing 9 12 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 82: ...Glossary GL 4 7900 A2 GB20 00 March 1998 This page intentionally left blank ...