MTU-M Status and Performance Functions
5-8
7900-A2-GB20-00
March 1998
3. Enter a time interval and press Enter.
The requested performance data appears.
Performance statistic data is stored in intervals of 1 minute, 15 minutes,
1 hour, 12 hours, 24 hours, and 7 days. Choosing a previous interval allows
you to view the last complete time interval. Selecting a current interval allows
you to view the most current time interval. Current intervals may not contain a
complete time cycle.
For example, if you type e (prev 1 hr) at the Select time period –> prompt,
the last full hour of data captured is displayed. Typing f (Curr 1 hr) displays
from 1–59 minutes of the most current data.
NOTE:
If you take the
xTU-C out of the MTU-M polling cycle (stoppoll from the
Maintenance Menu), performance data is no longer collected by the MTU-M.
You can view the most recently collected data by selecting a current time
period (options B, D, F, I, and K) that is greater than the amount of time the
xTU-C has been out of service.
Menu path: Main
→
Performance
→
xDSL circuit # (2-80)
→
time interval
The STU Line Error Statistics Table for STU #7 for the previous 15
minutes
CO: SDSL E1/G.703 CP: SDSL E1/G.703
CV
FAS
BPV
HTU-C Network
Input
14
0
0
Signal
HTU-R Network
Input
0
0
0
Signal
FAW A
FEBE A
CRC A
HTU-C
HDSL
2
46
16
Circuit
HTU-R
HDSL
2
33
34
Circuit
Hit return to continue ...
Summary of Contents for HOTWIRE 7900
Page 8: ...Contents iv 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 28: ...System Terminal Interface 4 6 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 72: ...Testing 9 12 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 82: ...Glossary GL 4 7900 A2 GB20 00 March 1998 This page intentionally left blank ...