MTU-M Maintenance Functions
6-5
7900-A2-GB20-00
March 1998
The following table provides a description of the operations parameters:
Field
Function
EEPROM values are
Displays the current status of the
xTU-C EEPROM values.
Polling Range
Displays the maximum and minimum xTU-C polling address.
The maximum possible xTU-C address is the right-most card
in the lowest nest. Refer to
Expansion Nest Numbering
Sequence
, in Chapter 2,
MTU-M Installation Procedures, for
the xTU numbering sequence.
Polling interval
Indicates the amount of time the MTU-M waits between
successive starts of the polling cycle. If all of the nest cards
can not be polled in this amount of time they may be
skipped.
Polling time-out
Denotes the maximum amount of time, in 256th seconds,
that the MTU-M will wait between the polling of each line
card.
Initial alarm on/off
setting
Indicates whether or not alarms are automatically displayed
on the system terminal as they occur.
Initial menu on/off
setting
Indicates whether or not menus are displayed on the system
terminal.
Console port baud rate
Indicates the baud rate for the system terminal.
Menu path: Main
→
Maintenance
→
sysconfig (Enter)
MTU–M Operations Parameters Menu
Select Command:
COMMAND
DESCRIPTION
max xtu
–
set the maximum xtu polling address
min xtu
–
set the minimum xtu polling address
polling interval –
set active circuit polling time interval
pollto
–
set polling time-out length
alarm
–
change initial alarm on/off setting
menu
–
change initial menu on/off setting
console
–
set console port baud rate
read
–
re–read the EEPROM
Quit
– Quit
Command
op param–>
Summary of Contents for HOTWIRE 7900
Page 8: ...Contents iv 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 28: ...System Terminal Interface 4 6 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 72: ...Testing 9 12 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 82: ...Glossary GL 4 7900 A2 GB20 00 March 1998 This page intentionally left blank ...