MTU-M Maintenance Functions
6-10
7900-A2-GB20-00
March 1998
Clearing MTU-M Alarms and Status Information (clear)
The clear option on the Maintenance menu is used to clear the current MTU-M
alarms and status information for a specific xTU.
NOTE:
Performance data is accumulated and stored by the MTU-M for each xTU.
Swapping or removing an xTU-C does not clear the data stored in these files
within the MTU-M. It is recommended that you clear performance statistics as
soon as possible after replacing or removing an xTU-C to avoid displaying
incorrect data.
"
Procedure
To clear status and alarms:
1. Type c at the maint –> prompt.
2. Press Enter.
3. Enter the ID of the xTU (xtu id) you wish to clear.
Menu path: Main
→
Maintenance
→
clear
Maint ->clear
Select Command:
COMMAND
DESCRIPTION
<2-80> –
enter xtu id <2-80>
–
(Current polling range: 2 to 16
Quit –
Quit Command
enter xtu id:
For example, to clear the status and alarms of the xTU-C in Slot 5 of the primary
nest, type 5 at the enter htu id: prompt and press Enter. The following message
appears:
maint –>
I HTU-C/R 5 MUI TASK Wed Oct 20 15:19:56 1997
status and alarms cleared