MTU-M Alarms
8-8
7900-A2-GB20-00
March 1998
Resetting the MTU-M
The reset option allows you to reset the system (MTU-M) or a specific xTU-C/R
pair.
"
Procedure
To reset the MTU-M:
1. At the MTU-M Main Menu screen MTU-M–> prompt, type r and press Enter.
The select command menu appears and prompts you to enter an xTU id or
system (to reset the MTU-M).
2. Type s at the Enter xtu id or system: prompt and press Enter.
The following message appears:
Are you sure you want to reset the MTU-M? (Y/N)?
3. Type Y and press Enter.
The MTU-M resets and clears all stored performance and alarm data.
After resetting the MTU-M, the status of each xTU-C displays.
Resetting the xTU-C/R
"
Procedure
To reset an individual xTU-C/R pair:
1. Type r at the MTU-M–> prompt and press Enter.
The select command menu appears and prompts you enter an xTU id or
system.
2. Type the ID of an xTU-C (2–80) at the Enter xtu id or system: prompt and
press Enter.
The following message appears:
Are you sure you want to reset the xTU-C/R? (Y/N)?
3. Type Y and press Enter.
The MTU-M sends a reset command to the
xTU-C/R pair. The xTU-C/R
resets and sends updated status information to the MTU-M.