Initial Startup and Configuration
3-12
7976-A2-GB20-10
August 1998
Configuring AutoRate
The M/SDSL AutoRate function is controlled from the Network Interface Options
screen and allows you to enable or disable AutoRate only from a unit configured
as an LTU. To access the Network Interface screen, follow this menu selection
sequence:
NOTE:
AutoRate is designed to find the best rate possible for your DSL loop
conditions. After the DSL loop is up units should be configured to run in fixed
rate.
Main Menu
→
Configuration
→
Network
Î
ÎÎ
main/config/network
Hotwire
Model: 7976
NETWORK INTERFACE OPTIONS
Margin Threshold:
–3db
Excessive Error Rate Threshold:
1E–6
Autorate
Disable
DSL Line Rate
528
Peer IP Address:
111.255.255.000 Clear
Circuit Identifier: Clear
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu
MainMenu
Exit
Save
"
Procedure
The AutoRate option is defaulted to Disable. To enable AutoRate:
1. Position the cursor in the AutoRate field and press the spacebar.
The AutoRate field toggles to Enable and the DSL Line Rate field displays.
2. Enter a DSL Line Rate and press Enter.
Your payload rate is set to a default value of 1984. Use Table 3-4,
Fixed Rate
Payload Rates and DSL Line Rates
, to set your DSL Line Rate and Payload
Rate according to whether you are configured for Voice (signaling) or Data.
Summary of Contents for Hotwire 7976
Page 56: ...Monitoring the Unit 4 14 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 66: ...Testing 5 10 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 78: ...Security 7 6 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 104: ...Standards Compliance for SNMP Traps B 6 7976 A2 GB20 10 August 1998...
Page 112: ...Technical Specifications D 2 7976 A2 GB20 10 August 1998...