Initial Startup and Configuration
3-16
7976-A2-GB20-10
August 1998
Saving Configuration Options
When changes are made to the configuration options through the Configuration
Edit/Display branch, the changes must be saved to take effect. Use the Save key
or Save Configuration screen.
"
Procedure
To save configuration options changes:
1. Press Ctrl-a to switch to the screen function key area below the dotted line.
2. Select Save and press Enter.
NOTE:
When Exit is selected before Save, or Save has been selected from any
menu in the Configuration/Edit branch, a Save Configuration screen appears
requiring a Yes or No response.
Î
Î
ÎÎ
ÎÎ
main/config/saveprompt
Hotwire
Model: 7976
SAVE CONFIGURATION
Save Changes? No
WARNING:
An answer of “yes” will cause the system
to reset as if it had been powered off and on!
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu
MainMenu
Exit
Command Complete
If the Telnet Session configuration option is changed, a message displays on the
Save Configuration screen warning that an answer of Yes will cause the Telnet
session to disconnect. Do not answer Yes unless you are prepared to disconnect.
If the DSL Mode configuration option is changed, a message displays on the
Save Configuration screen warning that an answer of Yes will cause the system
to reset. Do not answer Yes unless you are prepared to reset.
If you select . . .
Then . . .
Yes
The configuration is saved.
No
The Main Menu appears and changes are not saved.
Summary of Contents for Hotwire 7976
Page 56: ...Monitoring the Unit 4 14 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 66: ...Testing 5 10 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 78: ...Security 7 6 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 104: ...Standards Compliance for SNMP Traps B 6 7976 A2 GB20 10 August 1998...
Page 112: ...Technical Specifications D 2 7976 A2 GB20 10 August 1998...